Maytag MFS 25-35 Connection Of Water Supplies, Checking Rotation Direction, Water Connection

Models: MFS 25-35

1 30
Download 30 pages 31.94 Kb
Page 15
Image 15
4.5.5. CHECKING ROTATION DIRECTION

4.5.5. CHECKING ROTATION DIRECTION

CHECK IF THE DRUM ROTATES FROM THE FRONT VIEW IN CLOCKWISE DIRECTION DURING EXTRACTION. IF IT ROTATES IN OPPOSITE DIRECTION, DISCONNECT TWO PHASES

OF THE CONNECTION FROM THE FREQUENCY INVERTER TO THE MOTOR , SWITCH THEM OVER AND CHECK AGAIN THE ROTATION DIRECTION.

Fig. 4.5.C. Spin direction

4.5.6. MULTIPLE MACHINES IN LINE SIMPLE PHASE

When multiple single phase machines are connected to the same electrical network, it is necessary to connect the machines according to fig. 4.5.D. The phase of the frequency control and motor which is connected

to the terminal inside the machine, has to be connected alternatively for the first machine with the first phase L1 of the network, the second machine with the second phase L2, ... The fourth machine must again be connected to the first phase L1. This assures a better load of the electrical network.

Fig. 4.5.D. Multiple machines in line

4.6. CONNECTION OF WATER SUPPLIES

WATER CONNECTION

WATER HARDNESS

It is advisable to contact the water supplier for information concerning the properties of the water in your area. Good wash results are dependent also on the water hardness. For medium to very hard water, consideration should be made to make the water softer.

Only in some cases is the use of hard water desirable, such as adding softener in the linen.

The soap supplier can help you with making the right decisions concerning hard water, soft water, washing programs, type of soap and other related items to have the best wash results.

Characteristics

mmol / dm3

 

dH -

fH -

England

 

gr/gal

 

 

Germany

France

 

 

USA

soft

0 - 1,25

0

- 7°

0 - 12°

0 - 8,75°

0

- 3

 

 

 

 

 

 

 

 

medium

1,25 - 2,5

7

- 14°

12 - 25°

8,75 - 17,5°

3

- 7

hard

2,5 - 3,75

14 - 21°

25 - 37°

17,5 - 26,3°

7

- 15

 

 

 

 

 

 

very hard

above 3,75

above 21°

above 37°

above 26,3°

above 15

 

 

 

 

 

 

 

 

 

 

 

Tab.4.6.A.

 

 

 

14

INSTALLATION AND MAINTENANCE MANUAL

PUBLICATION DATE Sep 05 100646

Page 15