Maytag MFS 25-35 manual Waste channel cover 2.Drain elbow ∅76mm / 3“

Models: MFS 25-35

1 30
Download 30 pages 31.94 Kb
Page 17
Image 17
1.Waste channel cover

1.Waste channel cover

2.Drain elbow 76mm / 3“

3.Clamp

4.Waste channel

Without rubber feet : X1 = 55mm / 2.16" With rubber feet :

X1 = 73mm / 2.87"

X2 > 100mm / 3.93"

X3 > 20mm / 0.78"

Fig. 4.6.A. Design of the waste channel

The main drain pipe must have the capacity to be able to handle the total output of all connected machines. There must also be a hole every twenty meter in the drainpipe, fig. 4.6.B, pos. 1 to assure the good working of the drain. This allows air in the main drain and facilitates drainage of the water flow. Every time a machine is coupled on the drainpipe, the diameter of the tube or the width of the waste channel must be more. See, fig. 4.6.B, D1, D2, D3.

The recommended drain pipes diameter are:

D1 = 75 mm / 3“ for one machine

D2 = 100 mm / 4“ for two machines

D3 = 125 mm / 5“ for three machines

If the main drain cannot be sufficiently deodorized, install a deodorizer per machine.

Fig. 4.6.B. Recommended drain pipe diameters