Supply cable of the machine must have copper wires. The cross section of the supply wires depends on the supply voltage and on the total electrical power input of the machine (see table 4.3). The supply cable safety device against a
In all cases were the local standards requirements are higher, these has to be followed above the recommendation in table 4.5. If the local standards require installation of the earth leakage trip, we suggest to install one of 100 mA for the machines equipped with frequency inverter. The main contacts of the earth leakage trip must comply with the specified power input of the machine.
Power supply protection (A)
Recommended phase
conductor section
(mm2)
Protection conductor
section (mm2)
16 | 2,5 | 2,5 |
25 - 32 | 4 | 4 |
|
|
|
40 | 6 | 6 |
|
|
|
50 | 10 | 10 |
|
|
|
60 - 80 | 16 | 16 |
|
|
|
Tab 4.5.A. Recommended minimal conductor section
4.5.4. INSTALL SUPPLY CABLE TO THE MACHINE
! WARNING !
THE PROTECTIVE CONDUCTOR MUST BE LONGER SO THAT WHEN THE CABLE IS PULLED OUT ACCIDENTALLY, THIS CONDUCTOR IS DISCONNECTED AS THE LAST ONE!
Push the cable through the turnbuckle and connect the wires with the main switch. The diameter of the supply cable must between
If the cable is attached from above, it is recommended to make a sagging on the cable in front of its entry into the cable turnbuckle. In this way an ingress of the running condensed water into the bush and/or machine can be avoided. The manufacturer recommends to attach the cable from beneath.
1. L1, L2, L3 and N terminal
2. Turnbuckle
3. Turnbuckle nut
4. PE terminal
Fig. 4.5.B. Example of supply cable connection
100646 PUBLICATION DATE Sep 05 | INSTALLATION AND MAINTENANCE MANUAL | 13 |