Master Valve

A master valve or pump start is sometimes used in systems. When selected ON the controller provides constant output to that terminal when valves are on. See MASTER VALVE HOOK-UP. (page 6) The LAWN MASTER allows you to select this option on each program. The default is OFF for all programs.

To select your master valve ON:

Press NEXT until MASTER is displayed (after last valve)

Push ON to activate, push OFF to turn OFF.

O n N e x t O f f

QQ@

b

SKIP-You may select an interval from I- 30 days to water. For example, to water once every 10 days push the + button until display shows 10. (This option does not relate to the days of the month or week)

 

O n N e x t 0“

DAYS OF THE WEEK-Push ON to activate “DAYS”,push

8

@

NEXT to sequence through the individual days. Use the

 

$

+ button to select the day. Use the - button to eliminate

 

that day.

-1

AUTO START TIME

This sets the TIME OF DAY you wish to water. Each start time will start a cycle running each valve, one at a time, for their programmed watering duration, starting with the first valve and continuing until the last valve has completed its watering.

To set

Turn the dial to “AUTO START TIMES”. The display will show “START1”A

To set the desired time push + button until desired time is displayed. Pushing the

-button will CANCEL that start time.

OTHER START TIMES

To water more than once a day:

O n N e x t O f f

 

Press NEXT to set a second or third START TIME.

Repeat the above steps for each START TIME.

)m

DAYS TO WATERrplnon 0 This sets the DAYS of the week you wish to water.

There are 4 options you may use for convenience. Push

NEXT repeatedly to display options; press NEXT to select *~-ti=* the one that you prefer.

rw.l*u,-n

1.ODD-This option will water only ODD days

of the month. Automatically skips the 31st

pxcq

day of the month. Push ON to select

 

 

 

 

2. EVEN-This option will water only EVEN days of the

month.JULY Push ON to select.

)EVE::l ;;E;;i~

16 0 18 8 20 8 22

$$@26028@

page 6

Your programming is now completed for PROGRAM A. If you wish to use your other programs move PROGRAM

switch to position B or C and repeat the programming steps starting on page 8. Now return to the Auto Position. During operation B, all running valves will scroll on the display.

REVIEW

A B C

(TIs>

To REVIEW your entire program:

Set dial to “SPECIAL FEATURES”, select “PROGRAM”, Program display will show “Review”.

Push the + button, display will scroll all programmed information.

OTHER DIAL FUNCTIONS

SYSTEM % ADJUSTMENT: Dial in this position for simple seasonal adjustment of all your valve’s watering duration, When weather conditions return to normal this adjustment can be returned to normal (100%). This change will not permanently change your original programs.

To use

Select the PROGRAM you wish to adjust.

Set the dial to “SYSTEM % ADJUSTMENT’. This indicates all valves will water at 100% of their watering duration.

Use the + or - button to adjust, the display

will show selected change.

IptnX*l,-**

 

After adjusting return the dial to “AUTO”.

Note: Below 100% for less watering. Above 100% for more watering. 00% is off.

SPECIAL FEATURES

This position has three functions. In this position you may erase all programmed information (page programmed information (page , or set

8).

page 7

Page 6
Image 6
Genie LM-6, LM-9, LM-12 manual Qq@, Auto Start Time, Other Start Times, Review, Other Dial Functions, Special Features

LM-12, LM-9, LM-6 specifications

The Genie LM series is renowned in the realm of lift equipment, offering exceptional capabilities for a variety of aerial applications. Among the most notable models in this series are the LM-12, LM-6, and LM-9. Each of these lifts is designed to cater to the diverse needs of industries such as construction, maintenance, and warehousing, providing reliable access solutions with impressive performance and safety features.

The Genie LM-12 model stands out for its impressive lift height capability, reaching up to 12 feet. This model features a lightweight, compact design, making it highly maneuverable in tight spaces. A key characteristic is its user-friendly control system, which allows operators to manage the lift with ease. The LM-12 is equipped with a robust battery system, ensuring prolonged usage without the need for constant recharging. It also includes safety features such as automatic braking systems and non-slip platforms, ensuring a secure working environment.

Moving to the Genie LM-6, this model is well-suited for indoor applications due to its compact size and low weight, making it easy to transport and position. The LM-6 reaches a maximum working height of 6 feet, ideal for tasks such as shelving and painting in small spaces. This model is designed with an intuitive control panel, enhancing operator efficiency. Additionally, it incorporates advanced stability control systems that provide confidence while working at height.

The Genie LM-9, with its 9-foot lift height, strikes a perfect balance between the features of the LM-12 and LM-6. It’s versatile enough for both indoor and outdoor applications, making it a popular choice among contractors. The LM-9 is characterized by its rugged build quality and efficient battery system, providing reliable performance over extended periods. Safety remains a priority, with features designed to prevent tipping and ensure the safety of operators.

In conclusion, the Genie LM-12, LM-6, and LM-9 models each offer unique features tailored to various applications. From high lift capabilities to compact designs, these lifts encompass the reliability, safety, and efficiency that Genie is known for in the world of aerial access equipment. Whether it’s for indoor maintenance or outdoor construction work, the LM series continues to be an indispensable asset for professionals in a multitude of fields.