TheDBR-200 Relay module is worked when power input then
contacts will change over from N/C (Normally Close) to N/O
(NormallyOpen)
TheABD-110 timer allows for timed or latched functions of the
relay.In timer mode, the unit can in a x1 mode, (the timer is set
between 1 and 60 seconds.) Or a x10 mode (the timer is set
between 10 and 600 seconds.) In latch mode, the timer does
not apply,and the relay will remain energized unit a short is
appliedbetween the reset terminals.
DCvoltage averagely distributed to five output contacts, each
with PPTC re-settable fuse protection based on the dynamic
equilibriumof energy. Each OUTPUT is protected by individual
PPTCfrom over current; therefore each load of output may not
exceed1AMP.

DBR-200

RelayBoard

ABD-110

TimerBoard

GPD-3015

VoltageDistribution Board

Useful Gadgets
GIANNIINDUSTRIES, INC.
Theproducts are manufactured under an ISO
9001 QC 080000 Certified Quality
Management Program environment back its
productquality, performance and commitment
tocustomer satisfaction.
&
The product is warranted against defects in material and
workmanship while used in normal service for a period of 1
year from the date of sale to the original customer.The GEM
policy is one of continual development and improvement;
therefore GEM reserves the right to change specifications
withoutnotice.

Warranty

PowerInput: 8~30VAC or 11~30VDC
Current:45mA @ 12VDC
RelayOutput: Relay rated:
5A@ 24VAC, 5A@30VDC