Heath Zenith 5598 Least Sensitive, Most Sensitive, Operation, Manual Mode, Mode Switching Summary

Models: 5598

1 20
Download 20 pages 50.65 Kb
Page 5
Image 5
Least Sensitive

The sensor is less sensitive to motion directly towards it and more sensitive to motion across coverage area.

MotionMotion

 

Sensor

 

 

Least Sensitive

Most Sensitive

 

OPERATION

 

 

 

 

 

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

1, 5, or 10

 

x

 

Minutes

 

 

Manual

To Dawn*

 

x

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

MANUAL MODE

Mode Switching Summary

 

TEST

 

 

 

 

ON-TIME Switch at 1, 5, or

 

 

 

 

 

 

10 minutes

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

MANUAL MODE

 

 

 

back on*

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

Adjustment of Coverage Area

The sensor on this light fixture detects “motion”by the movement of heat across the coverage area.However, following are examples of objects that also produce heat and can cause the sensor to trigger:

• Pools of Water

• Air Conditioners

• Dryer Vents

• Animals

• Heating Vents

• Automobile Traffic

If you suspect that a heat source of this type is trig- gering the sensor, reduce the sensitivity.

SPECIFICATIONS

Range

Up to 30 ft. (9.1 m) [varies

 

with surrounding tempera-

 

ture].

Manual mode only works at night because daylight returns the sen- sor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

Sensing Angle

180°

Electrical Load

Up to 100 Watt Maximum

 

Incandescent

Bulb Type

Medium Base, Type “A”,

 

100 Watt Maximum

Sensor Capacity

360 Watt (3.0 A) Maximum

Power Requirements

120 VAC, 60 Hz

Operating Modes

TEST, AUTO, and

 

MANUAL MODE

ON-Timer

1, 5, 10 minutes

Test Timer

5 Seconds

... back on.

598-1314-00

Manual Mode Timer...... Dusk-to-Dawn

Page 5
Image 5
Heath Zenith 5598 Least Sensitive, Most Sensitive, Operation, Manual Mode, Mode Switching Summary, Specifications, Test