Heath Zenith 5598 Final Assembly, Testing and Adjustments, Maximum Range, Coverage Angle

Models: 5598

1 20
Download 20 pages 50.65 Kb
Page 4
Image 4
Final Assembly

Final Assembly

1.Push the wires into the junction box. Make sure none of the wires get pinched.

2.Slidethefixtureassemblyontothemountingscrews. Tighten decorative nuts removed in step 1 of Instal- lation section securely against fixture base.

Decorative Nut

Mounting Screw

Junction Box

3.Install one medium base light bulb (100 Watt maximum).

4.Place top cover onto fixture and attach using the two decorative nuts (included). Hand tighten only.

5.After completing the tests on page 5, caulk around fixture base with silicone weather sealant.

Decorative Nut

Top Cover

Light Bulb (100

Watt Maximum)

Fixture Assembly

Caulk Around

Fixture Base

Testing and Adjustments

1.Turn on the circuit breaker and light switch.

Note: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on wait 1 1/2 minutes.

2.Set:

ON-TIME switch to TEST SENSITIVITY dial to Midway

+

SEN

TEST 1 5 10

MINUTE

3.Walk through the coverage area noting where you are when the lights turn on. In TEST mode, light will stay on for 5 seconds after sensing motion and then turn off.

4.Adjust the SENSITIVITY to increase or decrease the range as needed. Too much sensitivity may cause false triggering due to heat sources in the coverage area (see Adjustment of Coverage Area or Troubleshooting section).

5.Set the amount of ON-TIME you want the light to stay on after motion is detected (1, 5, or 10 minutes).

 

180°

6 ft.

 

(1.8 m)

 

 

30 ft.

 

(9.1 m)

Maximum Range

Maximum

 

Coverage Angle*

 

(Top View)

598-1314-00

Page 4
Image 4
Heath Zenith 5598 owner manual Final Assembly, Testing and Adjustments, Maximum Range, Coverage Angle, Top View