Specifications
Model LP255
| U.S | (Metric) |
Volume | 26.0 GPM | (98 l/min) |
Discharge Pressure | 2175 PSI | 150 Bar) |
Inlet Pressure | Up to 90 PSI | Up to 6.2 Bar) |
Speed | Up to 1000 RPM | |
Plunger Diameter | 1.26” | (32 mm) |
Stroke | 1.65” | (42 mm) |
Crankcase Oil Capacity | 116 fl.oz | (3.43 liters) |
Temperature of Pumped Fluids | Up to 160oF | (70 oC) |
Inlet Ports | 2 x | |
Discharge Ports | 2 x 1" NPT | |
Crankshaft Mounting | Either Side | |
Shaft Rotation | Top of Pulley Towards Fluid End | |
Weight | 116 lbs | (52.7 Kg) |
Crankshaft Diameter | 1.38” | (35 mm) |
Valve Casing | Brass | |
Volumetric Efficiency @ 800 RPM | 0.96 | |
Mechanical Efficiency @ 800 RPM | 0.85 |
PULLEY INFORMATION
Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% tolerance on pumps output due to variations in pulleys, belts and motors among manufacturers.
1.Select GPM required, then select appropriate motor and pump pulley from the same line.
2.The desired pressure is achieved by selecting the correct nozzle size that corresponds with the
pump GPM.
HORSEPOWER INFORMATION
We recommend that a 1.1 service factor be speci- fied when s electing an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula:
HP = (GPM X PSI) / 1440
LP255 PULLEY SELECTION AND HORSEPOWER REQUIREMENTS
PUMP | MOTOR | RPM | GPM | 1000 PSI | 1500 PSI | 2000 PSI | 2175 PSI | |
PULLEY | PULLEY | |||||||
|
|
|
|
|
| |||
12.75" | 3.95" | 500 | 13 | 9.0 | 13.5 | 18.1 | 19.6 | |
12.75" | 4.35" | 640 | 16.6 | 11.5 | 17.3 | 23.1 | 25.1 | |
12.75" | 4.95" | 750 | 19.5 | 13.5 | 20.3 | 27.1 | 29.5 | |
12.75" | 5.35" | 805 | 20.9 | 14.5 | 21.8 | 29.0 | 31.6 | |
12.75" | 5.75" | 865 | 22.5 | 15.6 | 23.4 | 31.3 | 34.0 | |
12.75" | 6.15" | 920 | 23.9 | 16.6 | 24.9 | 33.2 | 36.1 | |
12.75" | 6.50" | 1000 | 26 | 18.1 | 27.1 | 36.1 | 39.3 |
6