Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installa- tion. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

1.The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.

2.The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of

1600 F, it is important to insure a positive head to the pump to prevent cavitation.

3.The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.

4.Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsa- tion. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the unloader.

5.Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction desig- nated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be obtained from the chart on page 3.

6.Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.

Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.

IMPORTANT OPERATING CONDITIONS

Failure to comply with any of these conditions invalidates the warranty.

1.Prior to initial operation, add oil to the crank- case so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL.

Use Giant oil

Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.

2.Pump operation must not exceed rated

pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.

3.Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.

4.Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.

2

Page 2
Image 2
Giant P220-3000 service manual Installation Instructions, Use Giant oil

P220-3000 specifications

The Giant P220-3000 is a groundbreaking piece of machinery in the realm of heavy equipment, particularly known for its applications in construction, mining, and earth-moving projects. This model stands out for its robust build and innovative technology, making it a staple choice for professionals looking for reliability and efficiency in demanding environments.

One of the key features of the Giant P220-3000 is its impressive engine performance. It is powered by a high-efficiency diesel engine that meets stringent emission standards, ensuring both environmental compliance and fuel efficiency. The engine is designed to provide substantial torque and power, enabling the machine to handle challenging tasks with ease. This ensures enhanced productivity and reduced operational costs, as less fuel consumption means increased profitability for users.

In terms of design, the Giant P220-3000 boasts a compact yet versatile structure. This makes it particularly suitable for working in confined spaces, where larger machines may struggle. Its articulated frame allows for exceptional maneuverability, coupled with a tight turning radius. Operators benefit from improved control and flexibility, whether navigating urban sites or tighter construction zones.

The lifting capacity of the Giant P220-3000 is noteworthy, capable of handling heavy loads without sacrificing stability. The unit’s hydraulic system is equipped with advanced technologies, including multi-functional attachments that can be switched out quickly to suit various applications. This versatility makes the machine not just a loader but a multi-tasking powerhouse, suited for tasks ranging from digging and loading to material handling and landscaping.

User comfort has also been a priority in the design of the Giant P220-3000. It features an ergonomic cabin with excellent visibility, intuitive controls, and ample legroom. This focus on operator comfort helps in reducing fatigue during long working hours, leading to increased productivity and safety on the job.

Additionally, the machine's maintenance is simplified with easy access to critical components, supporting efficient service schedules and minimizing downtime. Its durable build and high-quality materials ensure longevity, making it a wise investment for businesses.

Overall, the Giant P220-3000 exemplifies innovation in heavy machinery, combining powerful performance, versatility, and user-friendly features, establishing itself as a top choice in its class.