TECHNICAL DATA

TECHNICAL DATA

Data badge

On the bottom of the front frame behind the oven door.

Type of gas

This cooker must only be used with Natural Gas only, as specified on the appliance data badge.

Gas category

Natural Gas - I2H

Pressure setting

G20 Natural Gas @ 20 mbar

Pressure test point

Use the oven injector

Aeration - Fixed

Electrical supply/Load 220 - 240V ~ 50Hz

3290 - 3915W

Spark generator: Mains operated 6 outlet controlled by a single rocker switch at the LHS of the facia to individual electrodes. 2 outlets shorted to earth.

Warning: This cooker must be earthed.

Hob - Burners have burner heads and caps which are removable for cleaning. Concealed electrodes to each burner.

Countries of destination

GB - Great Britain, IE - Ireland

Fuel

Burner / Element

Nominal

Injector

 

 

Rate Qn

Size

 

 

 

 

Natural

Hob - LHF

1.0kW

77

Gas

Hob - LHR & RHR

2.0kW

104

 

Hob - RHF

3.0kW

129

 

Total heat input

8.0kW

-

 

 

 

 

26