Auto-Power Operation

5 A MPLIFI ER CO NTROLS

Auto-Power Operation

In AUTO-POWER mode, the amp is turned on automatically when receiving an audio signal.

This mode is useful when several amplifiers are used together in a multi-amp system or when the power amplifiers are not easily accessible.

Other display

If an abnormal situation is found by the TELOS 200, the front panel red light may turn ON, and the power of the amplifier is instantaneously set OFF.

The red Led indicates an over temperature situation, HF oscillation or DC signal has been detected.

Before re-starting the amplifier, detect what caused the problem and remove the cause first.

The amp will remain OFF with the red Led on until the user intervenes.

To unlock the amp from error mode, press the power key for >2 seconds. or restart the power sequence.