Goldstar LS242CE Auto clean Optional, Forced operation, Test operation, 24Room Air Conditioner

Models: LS242CE

1 29
Download 29 pages 57.43 Kb
Page 24
Image 24
 Auto clean (Optional)

Operating Instruction

 Forced operation Auto clean (Optional)

AUTO CLEAN

NOTICE

1.Whenever you press the AUTO CLEAN button, Auto Clean Function will be reserved and cancelled.

2.Auto Clean function works before and after cooling or dehumidification mode. For details, refer to the below points.

3.When the unit is started after the reservation of Auto Clean ,the Cool Start function operates and indoor Fan is started after 20 seconds.

4.When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean function, the air-conditioner circulates the indoor air in the Auto Clean mode with no more Cooling or Dehumidification operation. It lasts for 30 minutes.

5.If you press the AUTO CLEAN button again during the product operation , Auto Clean function will be cancelled.

During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy Dehumidification Operation can be removed.

During Auto Clean function, only Start/Stop button, Plasma button and AUTO CLEAN button are available.

Test operation Forced operation

Operation procedures when the remote control can't be used.

The operation will be started if the ON/OFF button is pressed.

If you want to stop operation, re-press the button.

 

 

 

ON/OFF

 

 

 

 

button

 

 

 

 

 

 

 

Cooling Model

 

Heat pump Model

 

 

 

 

 

 

 

 

Room Temp. 24°C(75.2°F)

21°C(69.8°F) Room Temp. < 24°C(75.2°F)

 

Room Temp. < 21°C(69.8°F)

 

 

 

 

 

 

 

 

 

Operating mode

Cooling

Cooling

Healthy Dehumidification

 

Heating

 

 

 

 

 

 

Indoor FAN Speed

High

High

High

 

High

 

 

 

 

 

 

Setting Temperature

22°C(71.6°F)

22°C(71.6°F)

23°C(73.4°F)

 

24°C(75.2°F)

 

 

 

 

 

 

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes.

During test operation, if remote controller signal is received, the unit operates as remote controller sets.

If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep".

If you want to stop the operation, re-press the button.

24Room Air Conditioner

Page 24
Image 24
Goldstar LS242CE Auto clean Optional, Forced operation, Test operation, 24Room Air Conditioner, Operating Instruction