Goodman Mfg service manual Product Design, GME80703BXC

Models: GME8

1 16
Download 16 pages 51.02 Kb
Page 7
Image 7
GME80703BXC*

PRODUCT DESIGN

PRESSURE SWITCH TRIP POINTS

AND USAGE CHART

 

TRIP POINT

ID BLOWER

MODEL

ID BLOWER

PRESSURE

PRESSURE

SWITCH

 

 

SWITCH

PART #

GME80703BXC*

-0.70

B1370158

 

 

 

GME80905CXC*

-0.75

B1370179

 

 

 

GME81155CXC*

-1.40

B1370156

 

 

 

*All installas above 7,000 ft. require a pressure switch change.

For installations in Canada, the GME8 furnace is certified only to 4,500 ft.

*Negative pressure readings are in inches of water column (*w.c.)

PRIMARY LIMIT

Part Number

20162903

 

 

Open Setting (°F)

160

 

 

GME80703BXC*

1

 

 

GME80905CXC*

1

 

 

GME81155CXC*

1

 

 

ROLLOUT LIMIT SWITCHES

Part Number

B1370145

 

 

Open Setting (°F)

300

 

 

GME80703BXC*

1

 

 

GME80905CXC*

1

 

 

GME81155CXC*

1

 

 

AUXILIARY LIMIT SWITCHES

Part Number

0130F00038

 

 

Open Setting (°F)

120

 

 

GME80703BXC*

1

 

 

GME80905CXC*

1

 

 

GME81155CXC*

1

 

 