PRODUCT DESIGN

Accessibility Clearances (Minimum)

Unobstructed front clearanace of 24" for servicing is rec- ommended.

Top clearance for horizontal confirguration - 1"

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS - INCHES

Sides

Rear

Front

Bottom

 

Vent

Top

SW

 

B

 

 

 

 

 

 

1

0

3

C

6

 

1

1

Approved for line contact in the horizontal postion.

*24" clearance for serviceability recommended.

**Single Wall Vent (SW) to be used only as a connector. Refer to venting tables outlined in the installation manual for additional venting requirements.

24" at front is required for servicing or cleaning.

Note: In all cases accessibility clearance shall take prece- dence over clearances from the enclosure where accessibil- ity clearances are greater. All dimensions are given in inches.

High Altitude Derate

When this furnace is installed at high altitude, the appropri- ate High Altitude orifice kit must be installed. This is re- quired due to the natural reduction in the density of both the gas fuel and combustion air as altitude increases. The kit will provide the proper design certified input rate within the specified altitude range.

INPUT PER BURNER - 22,500 BTUH NATURAL GAS / 20,000 BTUH L.P.

 

 

 

ELEVATION ABOVE SEA-LEVEL (FEET)

 

 

 

2000

3000

 

4000

4500

5000

6000

 

7000

8000

US BURNER

44/55

44/55

 

45/56

 

45/56

46/57

 

47/58

47/58

ORIFICE

 

 

 

 

 

 

 

 

 

 

 

 

 

CANADA BURNER

44/55

 

 

 

47/57

 

 

 

 

 

ORIFICE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HA-02 HIGH ALTITUDE CONVERSION KIT REQUIRED

Tabled data is based upon the furnace input being reduced for altitudes above sea level. U.S. 4% per 1,000 feet. Canada 10% derate for 2,000-4,000 feet.

High altitude kits are purchased according to the installa- tion altitude and usage of either natural or propane gas. Refer to the chart above for a tabular listing of appropriate altitude ranges and corresponding manufacturer’s high altitude Natu- ral Gas and Propane Gas kits. For a tabular listing of appro- priate altitude ranges and corresponding manufacturer's High Altitude Pressure Switch kits, refer to either the Pressure Switch Trip Points & Usage Chart in this manual or the Ac- cessory Charts in Service Instructions.

5

Page 5
Image 5