PRODUCT DIMENSIONS
GMS8[040-100]BB GMS81205D*BA GMS81405DNCC
Pre ssure Sw itch Trip Points
| Trip Point | ID Blow er | |
Model | ID Blow er | Pressure | |
Pressure | Sw itch | ||
| |||
| Sw itch | Part # | |
|
|
| |
GMS80403A*BB | B1370158 | ||
|
|
| |
GMS80603A*BB | B1370179 | ||
|
|
| |
GMS80604B*BB | B1370179 | ||
|
|
| |
GMS80804B*BB | B1370158 | ||
|
|
| |
GMS80805C*BB | B1370179 | ||
|
|
| |
GMS81005C*BB | B1370158 | ||
|
|
| |
GMS81205D*BA | 0130F00042 | ||
|
|
| |
GMS81405DNCC | 0130F00042 | ||
|
|
|
For installations in Canada, the GMS furnaces are certifed only to 4,500 ft.
* Negative pressure readings are in inches of water column (*w.c.)
PRIMARY LIMIT
Part Num ber | 20162901 | 20162904 | 20162903 | |
|
|
|
|
|
Open Setting (°F) | 210 | 15 | 0 | 160 |
|
|
|
| |
GMS80403A*BB | 1 | |||
|
|
|
|
|
GMS80603A*BB | 1 |
| ||
|
|
|
|
|
GMS80604B*BB | 1 |
| ||
|
|
|
|
|
GMS80804B*BB | 1 |
| ||
|
|
|
| |
GMS80805C*BB | 1 | |||
|
|
|
|
|
GMS81005C*BB | 1 |
| ||
|
|
|
| |
GMS81205D*BA | 1 | |||
|
|
|
| |
GMS81405DNCC | 1 |
ROLLOUT LIMIT SW ITCHES
Part Num ber | 10123529 | |
|
|
|
Open Setting (°F) | 30 | 0 |
|
|
|
GMS80403A*BB | 2 |
|
|
|
|
GMS80603A*BB | 2 |
|
|
|
|
GMS80604B*BB | 2 |
|
|
|
|
GMS80804B*BB | 2 |
|
|
|
|
GMS80805C*BB | 2 |
|
|
|
|
GMS81005C*BB | 2 |
|
|
|
|
GMS81205D*BA | 2 |
|
GMS81405DNCC | 2 |
|
AUXILIARY LIMIT SW ITCHES
Part Num ber | 0130F00038 | |
|
|
|
Open Setting (°F) | 12 | 0 |
|
|
|
GMS80403A*BB | 1 |
|
|
|
|
GMS80603A*BB | 1 |
|
|
|
|
GMS80604B*BB | 1 |
|
|
|
|
GMS80804B*BB | 1 |
|
|
|
|
GMS80805C*BB | 1 |
|
|
|
|
GMS81005C*BB | 1 |
|
|
|
|
GMS81205D*BA | 1 |
|
|
|
|
GMS81405DNCC | 1 |
|
7