PRODUCT DESIGN
Thermostats:
It is recommended that a
Thermostat | Man/Auto | Programmable | Cool | Heat | Batt. Powered | Batt. Bkup |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1213406* | Man. Or Auto | Yes | 2 | 3 | No | No |
|
|
|
|
|
|
|
1213407 | Man. Changeover | Yes | 2 | 2 | Yes | Yes |
|
|
|
|
|
|
|
1213411 | Man. Changeover | No | 2 | 2 | Yes | No |
|
|
|
|
|
|
|
*1213406 is the recommended model for the G*S* furnaces when used with a heat pump in a fossil fuel application.
It is NOT for use with the G*S8 as a sole heating source. 1213406 thermstats are 24V powered with battery
Filters: backup.
Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty
Upflow FiltersCabinet | Nominal | Approx. |
|
Width | Filter Size | Flow Area |
|
(in.) | (in.) | (in2) |
|
|
|
|
|
All | 16 x 25 x 1 | 400 |
|
|
|
|
|
Cabinet | Nominal | Approx. |
Width | Filter Size | Flow Area |
(in.) | (in.) | (in2) |
|
|
|
14 x 25 x 1 | 350 | |
21 | 16 x 25 x 1 | 400 |
20 x 25 x 1 | 500 | |
|
|
|
Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere in the duct system such as a central return.
MINIMUM FILTER SIZES for DISPOSABLE FILTERS
FURNACE INPUT | FILTER SIZE |
40M | 320 in2 |
60M | 483 in2 |
80M | 640 in2 |
100M | 800 in2 |
120M | 738 in2 |
140M | 738 in2 |
8