Thermostats:

PRODUCT DESIGN

Thermostats:

It is recommended that a single-stage heat, non-power robbing thermostat be used. Refer to the product marketing literature for a complete list of thermostats offered.

THERMOSTATS

Thermostat

Man/Auto

Programmable

Cool

Heat

Batt. Powered

Batt. Bkup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1213406*

Man. Or Auto

Yes

2

3

No

No

 

 

 

 

 

 

 

1213407

Man. Changeover

Yes

2

2

Yes

Yes

 

 

 

 

 

 

 

1213411

Man. Changeover

No

2

2

Yes

No

 

 

 

 

 

 

 

*1213406 is the recommended model for the G*S* furnaces when used with a heat pump in a fossil fuel application.

It is NOT for use with the G*S8 as a sole heating source. 1213406 thermstats are 24V powered with battery

Filters: backup.

Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty

Upflow Filters
SIDE RETURN

Cabinet

Nominal

Approx.

 

Width

Filter Size

Flow Area

 

(in.)

(in.)

(in2)

 

 

 

 

 

All

16 x 25 x 1

400

 

 

 

 

 

BOTTOM RETURN

Cabinet

Nominal

Approx.

Width

Filter Size

Flow Area

(in.)

(in.)

(in2)

 

 

 

17-1/2

14 x 25 x 1

350

21

16 x 25 x 1

400

24-1/2

20 x 25 x 1

500

 

 

 

Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere in the duct system such as a central return.

MINIMUM FILTER SIZES for DISPOSABLE FILTERS

FURNACE INPUT

FILTER SIZE

40M

320 in2

60M

483 in2

80M

640 in2
100M
800 in2
120M
738 in2
140M

738 in2

DISPOSABLE NOMINAL 300 F.M. FACE VELOCITY