Goodman Mfg dimensions Product Specifications, SS-GMVM96

Models: GMVM96

1 12
Download 12 pages 12.64 Kb
Page 3
Image 3
Specifications

Product Specifications

Specifications

 

GMVM96

GMVM96

GMVM96

GMVM96

GCVM96

GCVM96

GCVM96

 

0603BX

0805CX

1005DX

1155DX

0604CX

0805DX

1005DX

 

 

 

 

 

 

 

 

Heating Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Fire Input¹

60,000

80,000

100,000

115,000

60,000

80,000

100,000

 

 

 

 

 

 

 

 

High Fire Output¹

57,600

76,800

96,000

109,250

57,600

76,800

95,000

 

 

 

 

 

 

 

 

Low-Fire Steady-State Input¹

30,000

40,000

50,000

57,500

30,000

40,000

50,000

 

 

 

 

 

 

 

 

Low-Fire Steady-State Output¹

28,800

38,400

48,000

54,625

28,800

38,400

47,500

 

 

 

 

 

 

 

 

AFUE²

96

96

96

95

96

96

95

 

 

 

 

 

 

 

 

Tons AC @ 0.5” ESP

1.5-3.0

2.0-5.0

2.0-5.0

2.0-5.0

1.5-4.0

2.0-5.0

2.0-5.0

 

 

 

 

 

 

 

 

Temperature Rise Range (°F)

20-50

35-65

35-65

35-65

20-50

20-50

25-55

 

 

 

 

 

 

 

 

Circulator Blower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size (D x W)

10" X 8"

11" X 10"

11" X 10"

11" X 10"

10"X 10"

11" X 10"

11" X 10"

 

 

 

 

 

 

 

 

Horespower @ 1050 RPM

3/4

1

1

1

3/4

1

1

 

 

 

 

 

 

 

 

Speed

Variable

Variable

Variable

Variable

Variable

Variable

Variable

 

 

 

 

 

 

 

 

Vent Diameter³

2"

3"

3"

3"

2"

3"

3"

 

 

 

 

 

 

 

 

No. of Burners

3

4

5

5

3

4

5

 

 

 

 

 

 

 

 

Disposable Filter (in²)

576

960

960

972

641

854

854

 

 

 

 

 

 

 

 

Electrical Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. Circuit Ampacity (amps)⁴

6.0

14.2

14.2

14.2

6.0

14.2

14.2

 

 

 

 

 

 

 

 

Max. Overcurrent Protection⁵

15.0

15.0

15.0

15.0

15.0

15.0

15.0

 

 

 

 

 

 

 

 

Ship Weight (lbs)

135

145

170

170

139

165

170

 

 

 

 

 

 

 

 

¹Natural Gas BTU/h

²DOE AFUE based upon Isolated Combustion System (ICS)

³Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.

Gas Service Connection ½” FPT

Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

SS-GMVM96

www.goodmanmfg.com

3

Page 3
Image 3
Goodman Mfg dimensions Product Specifications, SS-GMVM96