Goodman Mfg dimensions GMVM96 Airflow Data — Cooling Speeds, Product Specifications

Models: GMVM96

1 12
Download 12 pages 12.64 Kb
Page 6
Image 6
GMVM96 Airflow Data — Cooling Speeds

Product Specifications

GMVM96 Airflow Data — Cooling Speeds

GMVM960603BX

GVMV960805CX

High Stage

Tap

Adjust

CFM*

 

 

 

 

Minus(-)

567

 

 

 

A

Normal

630

 

 

 

 

Plus (+)

693

 

 

 

 

Minus(-)

720

 

 

 

B

Normal

800

 

 

 

 

Plus (+)

880

 

 

 

 

Minus(-)

900

 

 

 

C

Normal

1000

 

 

 

 

Plus (+)

1100

 

 

 

 

Minus(-)

1089

 

 

 

D

Normal

1210

 

 

 

 

Plus (+)

1331

 

 

 

* @ .1" - .8" w.c. ESP

Low Stage

Tap

Adjust

CFM*

 

 

 

 

Minus(-)

351

 

 

 

A

Normal

390

 

 

 

 

Plus (+)

429

 

 

 

 

Minus(-)

495

 

 

 

B

Normal

550

 

 

 

 

Plus (+)

605

 

 

 

 

Minus(-)

612

 

 

 

C

Normal

680

 

 

 

 

Plus (+)

748

 

 

 

 

Minus(-)

720

 

 

 

D

Normal

800

 

 

 

 

Plus (+)

880

 

 

 

High Stage

Tap

Adjust

CFM*

 

 

 

 

Minus(-)

747

 

 

 

A

Normal

830

 

 

 

 

Plus (+)

913

 

 

 

 

Minus(-)

981

 

 

 

B

Normal

1090

 

 

 

 

Plus (+)

1199

 

 

 

 

Minus(-)

1314

 

 

 

C

Normal

1460

 

 

 

 

Plus (+)

1606

 

 

 

 

Minus(-)

1620

 

 

 

D

Normal

1800

 

 

 

 

Plus (+)

1980

 

 

 

* @ .1" - .8" w.c. ESP

Low Stage

Tap

Adjust

CFM*

 

 

 

 

Minus(-)

486

 

 

 

A

Normal

540

 

 

 

 

Plus (+)

594

 

 

 

 

Minus(-)

675

 

 

 

B

Normal

750

 

 

 

 

Plus (+)

825

 

 

 

 

Minus(-)

882

 

 

 

C

Normal

980

 

 

 

 

Plus (+)

1078

 

 

 

 

Minus(-)

1089

 

 

 

D

Normal

1210

 

 

 

 

Plus (+)

1331

 

 

 

GMVM961005DX

GMVM961155DX

High Stage

Tap

Adjust

CFM*

 

 

 

 

Minus(-)

711

 

 

 

A

Normal

790

 

 

 

 

Plus (+)

869

 

 

 

 

Minus(-)

990

 

 

 

B

Normal

1100

 

 

 

 

Plus (+)

1210

 

 

 

 

Minus(-)

1269

 

 

 

C

Normal

1410

 

 

 

 

Plus (+)

1551

 

 

 

 

Minus(-)

1647

 

 

 

D

Normal

1830

 

 

 

 

Plus (+)

2013

 

 

 

* @ .1" - .8" w.c. ESP

Low Stage

Tap

Adjust

CFM*

 

 

 

 

Minus(-)

459

 

 

 

A

Normal

510

 

 

 

 

Plus (+)

561

 

 

 

 

Minus(-)

639

 

 

 

B

Normal

710

 

 

 

 

Plus (+)

781

 

 

 

 

Minus(-)

819

 

 

 

C

Normal

910

 

 

 

 

Plus (+)

1001

 

 

 

 

Minus(-)

1044

 

 

 

D

Normal

1160

 

 

 

 

Plus (+)

1276

 

 

 

High Stage

Tap

Adjust

CFM*

 

 

 

 

Minus(-)

711

 

 

 

A

Normal

790

 

 

 

 

Plus (+)

869

 

 

 

 

Minus(-)

990

 

 

 

B

Normal

1100

 

 

 

 

Plus (+)

1210

 

 

 

 

Minus(-)

1269

 

 

 

C

Normal

1410

 

 

 

 

Plus (+)

1551

 

 

 

 

Minus(-)

1647

 

 

 

D

Normal

1830

 

 

 

 

Plus (+)

2013

 

 

 

Low Stage

Tap

Adjust

CFM*

 

 

 

 

Minus(-)

459

 

 

 

A

Normal

510

 

 

 

 

Plus (+)

561

 

 

 

 

Minus(-)

639

 

 

 

B

Normal

710

 

 

 

 

Plus (+)

781

 

 

 

 

Minus(-)

819

 

 

 

C

Normal

910

 

 

 

 

Plus (+)

1001

 

 

 

 

Minus(-)

1044

 

 

 

D

Normal

1160

 

 

 

 

Plus (+)

1276

 

 

 

Notes:

All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.

For most jobs, about 400 CFM per ton when cooling is desirable.

Operation is recommended below .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.

6

www.goodmanmfg.com

SS-GMVM96

Page 6
Image 6
Goodman Mfg dimensions GMVM96 Airflow Data — Cooling Speeds, Product Specifications