SPLIT SYSTEM HEATING PERFORMANCE

EXPANDED PERFORMANCE DATA

MODEL: GSH140421A* / CA*F4860D6A*+TXV / MBR2000**-1

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

 

-5

-10

 

MBh

49.8

47.1

44.4

41.5

39.6

38.4

35.6

32.9

31.2

28.8

26.6

25.1

24.1

21.7

19.2

16.8

14.3

11.7

 

Delta T

32.9

31.2

29.3

27.4

26.2

25.4

23.6

21.7

20.7

19.1

17.6

16.6

16.0

14.3

12.7

11.1

9.5

7.7

 

KW

3.20

3.14

3.08

3.02

2.99

2.96

2.91

2.85

2.89

2.83

2.77

2.73

2.71

2.65

2.59

2.53

2.46

2.40

 

AMPS

16.1

14.4

13.1

11.9

11.2

10.9

9.9

9.1

8.4

7.8

7.1

6.8

6.6

5.9

5.1

4.4

3.6

2.6

 

COP

4.56

4.39

4.21

4.02

3.88

3.79

3.59

3.38

3.16

2.98

2.81

2.69

2.61

2.40

2.17

1.94

1.70

1.43

 

EER

15.6

15.0

14.4

13.7

13.3

13.0

12.3

11.5

10.8

10.2

9.6

9.2

8.9

8.2

7.4

6.6

5.8

4.9

 

HI PR

222

213

205

196

191

188

180

173

166

158

152

148

146

140

135

129

125

120

 

LO PR

82

76

71

66

62

60

55

49

44

39

35

32

31

26

23

19

17

13

Above information is for nominal CFM and 70 degree indoor dry bulb.

MODEL: GSH140481A* / CA*F4860D6A*+TXV / MBR2000**-1

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

 

-5

-10

 

MBh

57.8

54.7

51.5

48.2

46.0

44.6

41.4

38.2

37.7

34.8

32.0

30.2

29.1

26.1

23.2

20.2

17.2

14.1

 

Delta T

34.5

32.7

30.8

28.8

27.5

26.6

24.7

22.8

22.5

20.8

19.1

18.1

17.4

15.6

13.8

12.1

10.3

8.4

 

KW

4.02

3.94

3.86

3.79

3.74

3.71

3.64

3.56

3.62

3.54

3.46

3.41

3.38

3.30

3.22

3.14

3.06

2.98

 

AMPS

20.9

18.7

17.0

15.5

14.6

14.2

12.9

11.8

10.9

10.1

9.2

8.8

8.6

7.7

6.6

5.8

4.7

3.4

 

COP

4.21

4.07

3.90

3.72

3.60

3.52

3.33

3.14

3.05

2.88

2.71

2.59

2.52

2.32

2.10

1.88

1.65

1.38

 

EER

14.4

13.9

13.3

12.7

12.3

12.0

11.4

10.7

10.4

9.8

9.3

8.9

8.6

7.9

7.2

6.4

5.6

4.7

 

HI PR

231

221

213

204

199

195

187

180

172

165

158

154

151

146

140

134

130

125

 

LO PR

76

70

66

60

57

55

51

45

41

36

32

30

29

24

21

18

15

12

Above information is for nominal CFM and 70 degree indoor dry bulb.

MODEL: GSH140601A* / CA*F4860D6A* +TXV / MBR2000**-1

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

 

-5

-10

 

MBh

69.1

65.5

61.6

57.6

55.0

53.3

49.5

45.7

41.0

37.9

34.9

32.9

31.7

28.4

25.2

22.0

18.8

15.4

 

Delta T

34.6

32.8

30.8

28.8

27.5

26.7

24.8

22.8

20.5

18.9

17.5

16.5

15.9

14.2

12.6

11.0

9.4

7.7

 

KW

4.21

4.12

4.04

3.96

3.91

3.87

3.79

3.71

3.71

3.62

3.54

3.49

3.45

3.36

3.28

3.20

3.11

3.02

 

AMPS

19.3

17.8

16.7

15.6

15.1

14.8

13.9

13.2

12.6

12.0

11.4

11.2

11.0

10.4

9.7

9.1

8.4

7.5

 

COP

4.81

4.65

4.46

4.26

4.12

4.03

3.82

3.60

3.24

3.06

2.89

2.76

2.69

2.47

2.25

2.01

1.77

1.49

 

EER

16.4

15.9

15.2

14.6

14.1

13.8

13.1

12.3

11.1

10.5

9.9

9.4

9.2

8.5

7.7

6.9

6.0

5.1

 

HI PR

228

219

210

201

197

193

185

178

170

163

156

152

150

144

139

133

128

124

 

LO PR

74

68

64

59

55

53

49

44

39

35

31

29

28

23

20

17

15

12

Above information is for nominal CFM and 70 degree indoor dry bulb.

High pressure is measured at the suction service valve ( the larger valve). Low pressure is measured at the gauge port connection.

AMPS = Outdoor unit amps (comp.+fan) KW = Total system power

22

Page 22
Image 22
Goodman Mfg RT6213004, GSH140301A, GSH140241A, GSH140181A, GSH140361A Model GSH140421A* / CA*F4860D6A*+TXV / MBR2000**-1