GSH14 SEER split system heat pump models are available in 1 1/2 through 5 ton sizes. They are designed for 208/230 volt single phase applications.

Air is drawn through the outdoor coil by a propeller fan, and is discharged vertically out the top of the unit. No additional restriction (ductwork) shall be applied.

The suction and liquid line connections are of the sweat type for field piping with refrigerant type copper. Non-back seating valves are factory installed to accept the field run copper. The total refrigerant charge for a normal installation is factory installed in the condensing unit. This charge is for the match- ing evaporator coil and a 15 foot refrigerant line set.

Systems should be properly sized by heat gain and loss calculations made according to methods of the Air Condi- tioning Contractors Association (ACCA) or equivalent. It is the contractors responsibility to ensure the system has ad- equate capacity to heat or cool the conditioned space.

GSH14 units use high-efficiency Copeland® scroll compres- sors and there are a number of design characteristics which are different from the scroll compared to the traditional recip- rocating compressor.

Due to their design Scroll compressors are inherently more tolerant of liquid refrigerant.

GSH14 model heat pumps do not use a reversing relay to energize the reversing valve. The reversing valve is energized in the cooling cycle through the "O" terminal on the room thermostat.

This unit is for outdoor installation only. Refer to minimum figure for clearances from the sides of the unit to full walls and other objects.

NOTE: This unit cannot be completely enclosed. At least one side must be unrestricted.

These clearances will help avoid air recirculation. If installing two or more units at the same location, allow at least 24 inches between units. If only one side is restricted (for ex- ample, against the outside wall of a house), the unit may be placed as close as 8" to that one wall.

DO NOT locate the unit:

*Directly under a vent termination for a gas appliance.

*Within 3 feet of a clothes drier vent

*Where the refreezing of defrost water would create a hazard

*Where water may rise into the unit.

NOT

 

B

OK!

RECOMMENDED

 

B

B

B

 

ModelADimensions - W x D x HGSH140181A*GSH140241A*GSH140301A*AA GSH140361A*GSC140421A*GSC140481A*GSC140601A*AA

 

 

 

 

 

 

 

 

 

OK!

 

 

C

 

 

 

C

 

 

AA

 

 

 

AA

 

 

 

AA

OK!

 

 

 

 

 

 

 

 

 

 

OK!OK!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual backgroundAManual backgroundManual backgroundManual backgroundManual background AAManual backgroundManual backgroundManual backgroundManual backgroundAA

Manual backgroundManual background C Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background C Manual backgroundManual backgroundManual backgroundManual backgroundManual background

 

 

 

 

 

Model

Dimensions - W x D x H

 

 

 

 

 

 

GSH140181A*

29 x 29 x 34¼

 

 

 

 

 

 

GSH140241A*

29 x 29 x 38¼

 

 

 

 

 

 

GSH140301A*

29 x 29 x 38¼

 

 

 

 

 

 

GSH140361A*

35½ x 35½ x 38¼

 

 

 

 

 

 

GSC140421A*

35½ x 35½ x 38¼

 

 

 

 

 

 

GSC140481A*

35½ x 35½ x 38¼

 

 

 

 

 

 

GSC140601A*

35½ x 35½ x 38¼

 

 

 

 

 

 

 

 

 