Graco 222800 Series C Grounding, Fire and Explosion Hazard Before operating the pump, ground

Models: 222800 Series C

1 28
Download 28 pages 32.95 Kb
Page 7
Image 7

Installation/Operation

Grounding

WARNING

FIRE AND EXPLOSION HAZARD Before operating the pump, ground the

system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 5.

1.Pump: use a ground wire and clamp (supplied). See Fig. 1. Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 1.5 mm@ (12 ga) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. Connect the other end of the wire to a true earth ground. Order Part No. 237569 Ground Wire and Clamp.

W

X

Y

Z

0864

Fig. 1

2.Air and fluid hoses: use only electrically conductive hoses.

3.Air compressor: follow manufacturer’s recommen- dations.

4.Spray gun: ground through connection to a prop- erly grounded fluid hose and pump.

5.Fluid supply container: follow your local code.

6.Object being sprayed: follow your local code.

7.Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continu- ity.

8.To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

308213 7

Page 7
Image 7
Graco 222800 Series C important safety instructions Grounding, Fire and Explosion Hazard Before operating the pump, ground