Operation

Adjustments

Set the actuating air to at least 75 psi (5.2 bar) and start the pump. Set the pump speed and pressure to obtain the desired flow rate. Always use the lowest pump speed nec- essary to achieve desired results.

Pressure Relief Procedure

FLUID INJECTION HAZARD

To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, always follow this procedure whenever you shut off the pump, when checking or servicing any part of the dispensing system, when installing, cleaning, or changing part of the valve and whenever you stop dispensing.

Operation

1.Shut off the power to the pump.

2.Close the bleed-type master air valve (required with air-powered pumps).

3.Actuate the dispensing valve to relieve pressure.

4.Open the pump drain valve (required in your system) to help relieve fluid pressure in the displacement pump. Actuating the dispensing valve to relieve pressure may not be sufficient. Have a container ready to catch the drainage.

5.Leave the drain valve(s) open until you are ready to dispense again.

If you suspect that the dispensing valve or hose is com- pletely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the hose end coupling and relieve pressure gradually, then completely loosen. Then clear the valve or hose.

Application Data

APPLICATION

 

 

 

TRAVEL SPEED IN MILES PER HOUR (KPH)

 

 

 

RECOMMENDATIONS*

 

 

 

Based on 15 mils (.381 mm) wet paint

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

5

6

7

8

9

10

11

12

 

(5)

(6)

(8)

(10)

(11)

(12)

(14)

(16)

(18)

(19)

 

 

 

 

 

 

 

 

 

 

 

Paint Tip Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For a 4 inch (101 mm)

433

433

439

439

443

443

445

449

453

457

wide line

LL5333

LL5333

 

 

LL5343

LL5343

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For a 6 inch (152 mm)

539

539

543

549

559

561

565

 

 

 

wide line

LL5439

LL5439

LL5443

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For a 12 inch (304 mm)

643

649

 

 

 

 

 

 

 

 

wide line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Pressure

 

 

 

 

 

 

 

 

 

 

psi (bar)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Paint System

1500-2000

1500-2000

1500-2000

1500-2000

1500-2000

1500-2000

1500-2000

1500-2000

1500-2000

1500-2000

(102)

(102)

(102)

(102)

(102)

(102)

(102)

(102)

(102)

(102)

 

 

 

 

 

 

 

 

 

 

 

 

* Coverage may vary depending on paint used.