Parts Drawing

Models 238893, 238894, 248090, and 255072

}35

32}

}31

3 }2

}33

11} 6

}34

7 }6

}28

}22

238893 with EZ Flush gauge port plug

238894 with fluid pressure gauge

248090 with fluid pressure gauge for LASD material

255072 High Resolution

Air-Operated Regulator

100 psi (0.7 MPa, 7 bar) Maximum Inbound Air Pressure

500 to 4000 psi (3.4 to 28 MPa, 34 to 276 bar) Regulated Fluid Outlet Pressure

 

 

 

 

 

8

 

 

 

}37

 

 

7*

7

 

 

 

 

 

 

 

 

 

 

 

 

12*

 

 

8

}30

 

 

13*

 

 

 

 

 

 

 

 

}36

 

 

19*

 

 

 

 

 

 

DETAIL OF MODEL 248090

 

 

 

 

1*

 

 

 

 

 

1

41

 

 

 

 

39

 

 

 

 

 

 

17*

42

4

 

 

38

 

 

 

 

 

4

 

 

 

 

 

 

 

 

42

 

40

 

 

 

 

 

41

 

 

 

 

 

 

 

 

 

 

 

3{n 2

 

 

}29

25

 

14{n

 

3

 

15{n

 

 

 

 

 

 

 

 

 

 

 

 

 

20{n

25

 

 

 

 

 

7

 

 

 

5

9

18{n 7

 

 

 

 

 

 

 

 

 

 

16{n

 

 

 

 

 

 

21{n

 

 

 

 

 

5{n 4

 

DETAIL

Torque Sequence for Regulator

Base Housing Screws (9)

41

23

06287

1Torque to 25 to 30 in-lb (2.8 to 3.4 NSm).

2Torque to 140 to 160 in-lb (16 to 18 NSm).

3Torque to 15 to 20 ft-lb (20 to 27 NSm).

4Torque to 30 to 35 ft-lb (41 to 48 NSm).

5Torque first to 20 to 25 ft-lb (27 to 34 NSm), then to 30 to 35 ft-lb (41 to 48 NSm) in the sequence shown in DETAIL at left.

6First torque to 30–33 in-lb (3.4–3.7 NSm) in alternating pattern then torque to 68–72 in-lb (7.7–8.1 NSm) in alternating pattern.

7Apply lithium-based grease when reassembling.

8 Torque to 75 to 80 in-lb (8.4 to 9.0 NSm).