Technical Data

 

Model 238890

Model 238892

Models 238894,

Model 244734

 

spring operated, with

spring operated, with

248090, and 255072

air operated, with

 

fluid pressure gauge

fluid pressure gauge

air operated, with

pressure sensor

 

Model 238889

Model 238891

fluid pressure gauge

ports

 

Model 238893

 

 

spring operated, with

spring operated, with

 

 

EZ Flush plug

EZ Flush plug

air operated, with EZ

 

 

 

 

Flush plug

 

Maximum fluid

6000 psi

6000 psi

6000 psi

6000 psi

inlet pressure

(41 MPa, 414 bar)

(41 MPa, 414 bar)

(41 MPa, 414 bar)

(41 MPa, 414 bar)

Regulated fluid

500–3000 psi

3000–5000 psi

500–4000 psi

500–4000 psi

outlet pressure

(3.4–21 MPa,

(21–34 MPa,

(3.4–28 MPa,

(3.4–28 MPa,

range

34–207 bar)

207–345 bar)

34–276 bar)

34–276 bar)

Maximum inbound

––

––

100 psi

100 psi

air pressure

 

 

(0.7 MPa, 7 bar)

(0.7 MPa, 7 bar)

Fluid inlet/outlet

3/8 npt(f)

3/8 npt(f)

3/8 npt(f)

1/2 npt(f)

size

 

 

1/2 npt(f) for 248090

 

 

 

 

 

Gauge port size

1/4 npt(f)

1/4 npt(f)

1/4 npt(f)

1/4 npt(f)

Fluid pressure

0–3000 psi

0–5000 psi

0–5000 psi

––

gauge (Models

(0–21 MPa,

(0–34 MPa,

(0–34 MPa,

 

238890, 238892,

0–207 bar)

0–345 bar)

0–345 bar)

 

and 238894)

 

 

 

 

Maximum flow

2 gpm (7.6 lpm)

2 gpm (7.6 lpm)

2 gpm (7.6 lpm)

2 gpm (7.6 lpm)

(in 65 cp material)

 

 

 

 

Maximum fluid

up to 15,000 cp

up to 15,000 cp

up to 15,000 cp

up to 15,000 cp

viscosity

 

 

 

 

Maximum operat-

120_ F (50_ C)

120_ F (50_ C)

120_ F (50_ C)

120_ F (50_ C)

ing temperature

 

 

 

 

Weight (with gauge)

7.0 lb (3.2 kg)

7.0 lb (3.2 kg)

11.7 lb (5.3 kg)

11.7 lb (5.3 kg)

Fluid diaphragms

PTFE with TPE

PTFE with TPE

PTFE with TPE

PTFE with TPE

 

backing

backing

backing

backing

Wetted parts (all

304, 316, 17–4 passivated SST, nickel– and cobalt–bound tungsten carbide, PTFE for all

models)

models; ceramic for model 248090, 244734, and 255072 only.

 

Adjustment tool

6 mm hex wrench

6 mm hex wrench

––

––

(spring-operated

 

 

 

 

models)

 

 

 

 

Air Requirements for Air-Operated Regulators (Models 238893, 238894, 248090, and 255072)

The following table shows the approximate air pressure needed to regulate the air-operated regulator to a given fluid outlet pressure.

 

 

 

 

 

 

 

Regulated Fluid Outlet Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models 238894, 248090,

 

 

 

 

 

 

Air Pressure

 

 

and 255072

 

 

Model 255072

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

psi

 

MPa

 

bar

psi

 

MPa

 

bar

psi

 

MPa

 

bar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

49

70

90

100

0.19

0.34

0.48

0.62

0.68

1.9

3.4

4.8

6.2

6.8

1000

2000

3000

4000

4000

7

14

21

28

28

69

138

207

276

276

550

1150

1800

2450

2700

4

8

12

17

19

40

80

120

170

190

20 308647

Page 20
Image 20
Graco 238890, 238892, 238894 important safety instructions Technical Data