Installation
Installation
WARNING
SPECIAL CONDITIONS FOR SAFE USE
Equipment must comply with the following conditions to avoid a hazardous condition which can cause fire or explosion.
• All label and marking material must be cleaned with a damp cloth (or equiva- lent).
•The electronic monitoring system is required to be grounded. See Ground- ing instructions in your pump operation manual.
Prepare to Install
1.Relieve the pressure. Follow instructions in your Operation manual.
2.Disconnect the air line to the pump.
4.Select the Diagnostic Codes card that matches the operator’s preferred language. Insert it in the inside of the DataTrak cover for quick reference.
ti14223a
5.DataTrak with runaway protection: Attach the sole- noid (S) and bracket (4d) to the air valve. Use the same screws (4c) that attach the air valve to the manifold, as shown.
4c
Install the Kit
1.Mount the bracket to the wall. Use approximately 3/8 in. bolts or screws.
2.Install the DataTrak module (1) on the bracket.
1
ti14055a
4d
S
ti14058a
3.Conversion Kits include a new air valve that is com- patible with the solenoid. Remove the old air valve and gasket from the pump, and install the replace- ment air valve and gasket.
4 | 313840G |