DataTrak Operation
Calibration Procedure
1.Press and hold for 5 seconds until Setup menu appears.
2.Press once. Change flow rate units to cycles/min.
3.Return to Run Screen. Press and hold for three seconds to reset batch totalizer.
4.Dispense fluid from pump into a graduated con- tainer.
5.Convert the actual volume dispensed to cubic centi- meters (cc). See conversion chart.
Units Measured | Multiply by | To get |
|
|
|
Gallons (U.S.) | 3785 | cc |
|
|
|
Gallons (Imp) | 4546 | cc |
|
|
|
Liters | 1000 | cc |
|
|
|
Quarts | 946 | cc |
|
|
|
Ounces (U.S.) | 29.57 | cc |
|
|
|
Ounces (Imp) | 28.41 | cc |
|
|
|
Cubic inches | 16.39 | cc |
|
|
|
Cubic feet | 28,317 | cc |
|
|
|
Pints | 473 | cc |
|
|
|
cc | 1 | cc |
|
|
|
6.Divide the actual volume dispensed (cc) by the num- ber of cycles indicated on the DataTrak batch total- izer display.
7.Press to enter the Setup screen. Enter the number from Step 6 in field 2 of the Setup screen.