Graco 24K863, 24K861, 24B796, 24B795 Calibration Procedure, Units Measured, Multiply by, To get

Models: 24B798 24K864

1 18
Download 18 pages 12.05 Kb
Page 9
Image 9

DataTrak Operation

Calibration Procedure

1.Press and hold Calibration Procedure for 5 seconds until Setup menu appears.

2.Press Units Measured once. Change flow rate units to cycles/min.

3.Return to Run Screen. Press and hold Multiply by for three seconds to reset batch totalizer.

4.Dispense fluid from pump into a graduated con- tainer.

5.Convert the actual volume dispensed to cubic centi- meters (cc). See conversion chart.

Units Measured

Multiply by

To get

 

 

 

Gallons (U.S.)

3785

cc

 

 

 

Gallons (Imp)

4546

cc

 

 

 

Liters

1000

cc

 

 

 

Quarts

946

cc

 

 

 

Ounces (U.S.)

29.57

cc

 

 

 

Ounces (Imp)

28.41

cc

 

 

 

Cubic inches

16.39

cc

 

 

 

Cubic feet

28,317

cc

 

 

 

Pints

473

cc

 

 

 

cc

1

cc

 

 

 

6.Divide the actual volume dispensed (cc) by the num- ber of cycles indicated on the DataTrak batch total- izer display.

7.Press To get to enter the Setup screen. Enter the number from Step 6 in field 2 of the Setup screen.

313840G

9

Page 9
Image 9
Graco 24K863, 24K861, 24B796, 24B795, 24K864, 24B793, 24B771, 24B794 Calibration Procedure, Units Measured, Multiply by, To get