Check DataTrak Operation

6.Use the screw provided to attach the reed switch just behind the air inlet. Remove the muffler, if needed, for easier access. Rotate the air inlet fitting as needed so the wrench flat clears the reed switch.

ti14056a

7.Connect the DataTrak cable to the 5-pin connector on the reed switch. Reconnect the air line to the motor.

5-pin connector

Installation

a.The DataTrak pump icon should move when the air motor changes direction.

b.The Grand Totalizer and Batch Totalizer should advance.

4.DataTrak with runaway protection: Check for proper runaway operation.

a.Run the air motor at a speed faster than the run- away limit.

b.After 5 consecutive cycles, the DataTrak should stop the pump and display the run- away diagnostic screen.

c.To reset, turn the pressure off, then push Setup Mode, page 7. on the DataTrak module.

d.After resetting, turn on the air supply. The air motor should run. Shut off the air until ready to pump.

NOTE: If the DataTrak does not reset, turn air pressure down, then use a screwdriver to push the solenoid release button on the side of the air valve.

ti14054a

8.Secure DataTrack data cable. A plastic spiral con- duit is provided to help prevent chafing.

Check DataTrak Operation

1. Enable runaway

and set the runaway limit. See

Setup Mode, page 7.

 

2.Run the air motor at a speed slower than the run- away limit.

3.Check for proper reed switch operation.

ti14263a

5. Configure the DataTrak as needed. See page 7.