Instructions

Component Wiring

1.Before connecting wires to components verify the Connector end of the cable is NOT plugged into the GLC2200 controller.

2.Remove 2 to 3 inches of the outer insulation (a) from bare end of the cable as shown FIG. 4.

.

a

FIG. 4

3.Strip each wire (b) you are using for the installation as shown in FIG. 5.

NOTE: It is not necessary to strip all of the wires; only strip the wires needed for your installation.

b

FIG. 5

Wiring Diagram

4.Using the Wiring Key Table, connect components to wires matching each wire color and pin location.

Verify all negative and positive wire colors are cor- rectly assigned.

NOTE: The second column of the Wiring Key Table is provided for the user to record the wire color assigned to each component.

5.Plug connector into the GLC2200 unit matching pin numbers to Connector Identification Label.

NOTE: The connector can only be plugged into the GLC2200 one way. The clip (c) should be facing down when the connector is correctly oriented.

c

FIG. 6

M

V

1

6

2

7

3

4

5

-

 

 

 

8

9

10

+

 

9A Fuse

FIG. 7

M = Motor pump power or solenoid

V = Electric vent valve for injector-based systems

3A2992B

3

Page 3
Image 3
Graco 24P686, 24P687 important safety instructions Component Wiring, Wiring Diagram