Graco 24P822 important safety instructions Setup Screen 3 Key

Models: 24P822

1 40
Download 40 pages 63.02 Kb
Page 19
Image 19

Setup Screen 3

Use this screen to set your flow rate settings for a selected pump and profile. In pressure mode, you will set a maximum flow rate. In flow mode, you will set a target flow rate. In either pressure or flow mode, a minimum flow rate may be set if desired. See Setup Screen 4 to specify how the system will respond if the pump begins to operate outside of the set boundaries.

Setup Screen 3 Key

Enter the screen to set or change preferences.

Pump selection — See Step 1.

Profile selection — See Step 2.

Flow rate maximum— See Step 3.

Flow rate target— See Step 4.

Flow rate minimum — See Step 5.

Press to accept the selections.

This softkey is disabled by default, and only appears if the “Profile Lock” box is checked on Setup Screen 15, page 29. Press to activate the profile just edited.

Exit data editing.

NOTE: With flow rate units of cc/min, the maximum value that can be displayed is 9999. If the field displays ####, the saved value is out of range. Go to Setup Screen 13, page 27 and change the flow rate to a larger unit. Return to this screen and reduce the setting to a lower value that will be within the display’s range, then reset the flow rate units to cc/min.

Setup Screens

1.For systems with multiple pumps and one display, select the desired pump (1 to 8), using the pull-down menu.

2.Select the desired profile (1 to 4), using the pull-down menu.

3.In flow mode, set a target flow rate. This field is not used in pressure mode.

Figure 19 Flow Mode: Flow Rate Settings

4.In pressure mode, set the maximum flow rate.The software will calculate the number of pump cycles needed to achieve that flow rate. This field is not used in flow mode.

NOTE: The motor will not run if the profile does not have a maximum flow rate setting.

Figure 20 Pressure Mode: Flow Rate Settingss

5.If desired, set a minimum flow rate.

3A2527D