Installation
Cable Connection
Order an accessory cable (C) from Table 1. Connect the cable to Port 3 on the bottom of the control module (see Fig. 2). Connect the other end to the power terminal (PT) on the motor (see Fig. 3). Connect other cables as described in Table 2.
Table 1 CAN Cables |
| |
Cable Part | Description |
|
No. |
|
|
16P911 | Intrinsically safe CAN cable, female |
|
| x female, 3 ft (1 m) |
|
16P912 | Intrinsically safe CAN cable, female |
|
| x female, 25 ft (8 m) | Figure 2 ADCM Connectors |
Table 2 ADCM Cable Connections
ADCM Port | Connector Purpose |
Number |
|
|
|
1 | Fiber Optic RX - to PLC |
|
|
2 | Fiber Optic TX - to PLC |
|
|
3 | Power and CAN communication |
|
|
4 | Start/stop input |
|
|
5 | Fiber Optic RX - to next ADCM |
|
|
6 | Fiber Optic TX - tos next ADCM |
7 | Pressure transducer 1 |
|
|
8 | BPR control |
|
|
9 | Not used |
|
|
10 | Pressure transducer 2 |
|
|
Figure 3 Motor Power Terminal
3A2527D | 5 |