Important Isocyanate (ISO) Information

Changing Materials

NOTICE

Changing the material types used in your equipment requires special attention to avoid equipment damage and downtime.

When changing materials, flush the equipment multiple times to ensure it is thoroughly clean.

Always clean the fluid inlet strainers after flushing.

Check with your material manufacturer for chemi- cal compatibility.

When changing between epoxies and urethanes or polyureas, disassemble and clean all fluid com- ponents and change hoses. Epoxies often have amines on the B (hardener) side. Polyureas often have amines on the B (resin) side

6

332198C

Page 6
Image 6
Graco 24R021 important safety instructions Changing Materials