Graco 24R021 important safety instructions Important Isocyanate ISO Information

Models: 24R021

1 16
Download 16 pages 62.67 Kb
Page 5
Image 5

Important Isocyanate (ISO) Information

Important Isocyanate (ISO) Information

Isocyanates (ISO) are catalysts used in two component materials.

Isocyanate Conditions

Spraying or dispensing materials containing isocya- nates creates potentially harmful mists, vapors, and atomized particulates.

Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions related to isocyanates.

Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventila- tion in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area.

To prevent contact with isocyanates, appropriate per- sonal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area.

Material Self-ignition

Some materials may become self-igniting if applied too thick. Read material manufacturer’s warnings and material MSDS.

Keep Components A (ISO) and B (RES) Separate

Cross-contamination can result in cured material in fluid lines which could cause serious injury or damage equipment. To prevent cross-contamination:

Never interchange component A (ISO) and com- ponent B (RES) wetted parts.

Never use solvent on one side if it has been con- taminated from the other side.

Moisture Sensitivity of

Isocyanates

Exposure to moisture (such as humidity) will cause ISO to partially cure; forming small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity.

NOTICE

Partially cured ISO will reduce performance and the life of all wetted parts.

Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere. Never store ISO in an open container.

Keep the ISO pump wet cup or reservoir (if installed) filled with appropriate lubricant. The lubricant creates a barrier between the ISO and the atmosphere.

Use only moisture-proof hoses compatible with ISO.

Never use reclaimed solvents, which may contain moisture. Always keep solvent containers closed when not in use.

Always lubricate threaded parts with an appropri- ate lubricant when reassembling.

NOTE: The amount of film formation and rate of crystal- lization varies depending on the blend of ISO, the humidity, and the temperature.

Foam Resins with 245 fa Blowing Agents

Some foam blowing agents will froth at temperatures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system.