Graco 256714, 256713, 223540, 224348 Troubleshooting, Problem, Cause, Solution

Models: 224348 223540 256714 256713

1 28
Download 28 pages 62.8 Kb
Page 13
Image 13
Troubleshooting

Troubleshooting

Problem WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 9.

Before servicing this equipment always make sure to relieve the pressure.

Check all possible problems and solutions before disassembling the pump.

Problem

Cause

Solution

 

 

 

Pump fails to operate

Restricted line or inadequate air sup-

Clear; Increase air supply.

 

ply

 

 

 

 

 

Insufficient air pressure; closed or

Open, clean.

 

clogged air valves, etc.

 

 

 

 

 

Exhausted fluid supply

Refill; purge all air from pump and

 

 

fluid lines.

 

 

 

 

Damaged air valving mechanism;

Service air motor (see manual

 

stalling

306982 or 307043).

 

 

 

 

Dried fluid seizure of displacement

Clean, check or replace throat pack-

 

rod (1)

ings (3, 25); always stop the pump at

 

 

the bottom of its stroke and keep the

 

 

wet-cup filled with compatible solvent.

 

 

 

Pump operates, but output low on

Restricted line or inadequate air sup-

Clear; increase air supply.

both strokes

ply

 

 

 

 

 

Insufficient air pressure; closed or

Open, clean.

 

clogged air valves, etc.

 

 

 

 

 

Exhausted fluid supply

Refill; purge all air from pump and

 

 

fluid lines.

 

 

 

 

Clogged fluid line, valves, etc.

Clear*.

 

 

 

 

Packing nut (14) too tight

Loosen (see page 10).

 

 

 

 

Loose packing nut (14) or worn throat

Tighten packing nut (see page 10);

 

packings (3, 25)

replace throat packings.

 

 

 

Pump operates, but output low on

Held open or worn intake valve.

Clear; service.

down stroke

 

 

 

 

 

Pump operates, but output low on

Held open or worn fluid piston valve

Clear; service.

up stroke

or packings (29, 30)

 

 

 

 

Erratic or accelerated operation

Exhausted fluid supply

Refill; purge all air from the pump and

 

 

fluid lines.

 

 

 

 

Help open or worn intake valve.

Clear; service.

 

 

 

 

Help open or worn fluid piston valve

Clear; service.

 

or packings (29, 30)

 

*To determine if the fluid hose or gun is obstructed, relieve the pressure. Disconnect the fluid hose and place a container at the pump fluid outlet to catch any fluid. Turn on the air just enough to start the pump (about 20–40 psi [140–280 kPa, 1.4–2.8 bar]). If the pump starts when the air is turned on, the obstruction is in the fluid hose or gun.

308118 13

Page 13
Image 13
Graco 256714, 256713, 223540, 224348 important safety instructions Troubleshooting, Problem, Cause, Solution