Graco 224348 Technical Data 10 1 President, 308118, Pressure, Outlet, Pump, Air Consumption

Models: 224348 223540 256714 256713

1 28
Download 28 pages 62.8 Kb
Page 23
Image 23
PRESSURE

Technical Data (10:1 President)

Fluid Outlet Pressure Chart

 

MPa, BAR

PSI

 

 

 

CPM

 

 

 

 

20

40

60

80

100

 

12.5, 125

1800

 

 

 

 

 

 

 

 

 

11.0, 110

1600

 

A

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE

9.6, 96

1400

 

 

 

 

 

 

8.4, 84

1200

 

 

 

 

 

 

7.0, 70

1000

 

B

 

 

 

 

 

 

 

 

 

 

 

OUTLET

5.6, 56

800

 

 

 

 

 

 

 

 

 

 

 

4.2, 42

600

 

C

 

 

 

 

PUMP

2.8, 28

400

 

 

 

 

 

 

1.4, 14

200

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

GPM

0

1

2

3

4

5

 

 

l/min

 

3.8

7.6

11.4

15.2

19.0

A1.25 MPa, 12.5 bar (180 psi) air pressure

B0.7 MPa, 7 bar (100 psi) air pressure

C0.49 MPa, 4.9 bar (70 psi) air pressure

D0.28 MPa, 2.8 bar (40 psi) air pressure

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with selected fluid outlet pressure curve. Curve slopes from left to right.

Follow left to scale and read outlet pressure.

PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
AIR CONSUMPTION

Air Consumption Chart

m3/min CFM

 

 

 

CPM

 

 

 

 

20

40

60

80

100

2.800

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.240

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

1.6860

1.12

40

 

 

 

B

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

0.56

20

 

 

 

D

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPM

0

1

2

3

4

5

l/min

 

 

 

 

3.8

7.6

11.4

15.2

19.0

PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)

A1.25 MPa, 12.5 bar (180 psi) air pressure

B0.7 MPa, 7 bar (100 psi) air pressure

C0.49 MPa, 4.9 bar (70 psi) air pressure

D0.28 MPa, 2.8 bar (40 psi) air pressure

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve.

Curve slopes from right to left. Follow left to scale and read air consumption.

308118 23

Page 23
Image 23
Graco 224348 Technical Data 10 1 President, 308118, Pressure, Outlet, Pump, PUMP DELIVERY Test Fluid No. 10 Motor Oil