Installation
NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the Parts Drawing.
NOTE: Contact you Graco distributor for available Graco accessories. If you supply your own accesso- ries, be sure they are adequately sized and pressure- rated to meet the system’s requirements.
The Typical Installation shown on page 6 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs.
System Accessories
Refer to the Typical Installation on page 6.
WARNING
A
The
The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient.
Mounting Accessories
Mount the pump (A) to suit the type of installation planned. The pump dimensions and mounting hole layout are shown on page 26.
The pump is supplied with a bung adapter. To mount the pump, loosen the bung adapter screw and slide the adapter off the pump. Screw the bung adapter secure- ly into the bung hole on the cover of the supply drum. Carefully lower the pump through the bung adapter and into the drum until it rests on the bottom, then pull it back up 1/2 in. (13 mm). Tighten the bung adapter screw to hold the pump in this position. Open the drum’s vent plug to prevent a vacuum from forming in the drum.
Air and Fluid Hoses
Be sure all air and fluid hoses are properly sized and
Connect a electrically conductive fluid hose (L) to the fluid filter (K), if used, or directly to the pump’s fluid outlet.
Use a electrically conductive 1/2 in. ID (minimum) air hose (H) to supply air to the pump.
Air Line Accessories
Install the following accessories in the order shown in the Typical Installation, using adapters as necessary.
DAn air line lubricator (C) provides automatic air motor lubrication.
DA
DA pump runaway valve (B) senses when the pump is running too fast and automatically shuts off the air to the motor. A pump which runs too fast can be seriously damaged.
DAn air regulator (E) controls pump speed and outlet pressure by adjusting the air pressure to the pump. Locate the regulator close to the pump, but upstream from the
DAn air line filter (F) removes harmful dirt and moisture from the compressed air supply.
DA second
Fluid Line Accessories
Install the following accessories in the positions shown in the Typical Installation, using adapters as neces- sary:
DA fluid drain valve (J) is required in your system to relieve fluid pressure in the hose and gun (see the WARNING at left). Install the drain valve point- ing down, but so the handle points up when opened.
DA fluid filter (K) filters harmful particles from the fluid.
DA spray gun (M) dispenses the fluid. The gun shown in the Typical Installation is an airless spray gun.
308118 7