Technical Data (5:1 Monark)
Fluid Outlet Pressure Chart
| MPa, BAR | PSI |
|
|
| CPM |
|
|
|
| 24 | 48 | 72 | 96 | 120 | ||
| 5.6, 56 | 800 |
| |||||
|
|
|
|
|
|
| ||
PRESSURE |
|
|
| A |
|
|
|
|
4.2, 42 | 600 |
|
|
|
|
|
| |
2.8, 28 | 400 |
|
|
|
|
|
| |
OUTLET |
| B |
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
PUMP | 1.4, 14 | 200 |
| C |
|
|
|
|
|
|
| D |
|
|
|
| |
|
|
|
|
|
|
|
| |
|
| 0 |
|
|
|
|
|
|
|
| GPM | 0 | 1 | 2 | 3 | 4 | 5 |
|
| l/min |
| 3.8 | 7.6 | 11.4 | 15.2 | 19.0 |
A1.25 MPa, 12.5 bar (180 psi) air pressure
B0.7 MPa, 7 bar (100 psi) air pressure
C0.49 MPa, 4.9 bar (70 psi) air pressure
D0.28 MPa, 2.8 bar (40 psi) air pressure
To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):
1.Locate desired delivery along bottom of chart.
2.Read vertical line up to intersection with selected fluid outlet pressure curve. Curve slopes from left to right.
Follow left to scale and read outlet pressure.
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
Air Consumption Chart
AIR CONSUMPTION
m3/min CFM 1.120 40
0.896 32
0.672 24
0.448 16
0.224 8
CPM
24 48 72 96 120
A
B
C
D
A1.25 MPa, 12.5 bar (180 psi) air pressure
B0.7 MPa, 7 bar (100 psi) air pressure
C0.49 MPa, 4.9 bar (70 psi) air pressure
D0.28 MPa, 2.8 bar (40 psi) air pressure
To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):
1.Locate desired delivery along bottom of chart.
2.Read vertical line up to intersection with selected air consumption curve.
Curve slopes from right to left. Follow left to scale and read air consumption.
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GPM | 0 | 1 | 2 | 3 | 4 | 5 | ||||||||||||||||||
l/min |
|
|
|
| 3.8 | 7.6 | 11.4 | 15.2 | 19.0 |
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
308118 25