Unclogging Spray Tip/Guard Assembly

Unclogging Spray Tip/Guard Assembly

5.Disengage trigger lock, put prime/relief valve DOWN to spray position, and resume spraying.

Do not operate or spray near children. Do not aim the sprayer at, or spray any person or animal. Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.

1.To unclog tip obstruction, engage trigger lock and pull relief valve UP to release pressure.

ti14995a

6.If tip is still clogged, you may have to repeat steps 1 - 5 and rotate the tip from SPRAY to UNCLOG several times. Repeat step 1 to release pressure, remove and clean filter, or replace with new tip assembly.

ti14994a

ti14999a

2. Reverse spray tip to UNCLOG position.

3.Aim sprayer at waste area, disengage trigger lock, and put prime/relief valve DOWN to spray position. Pull trigger to clear clog.

ti14989a

NOTE: Filter assembly is reverse-threaded: Turn left (or counter-clockwise) to install. Turn right (or clockwise) to remove.

7.If obstruction is cleared, engage trigger lock and rotate arrow-shaped handle back to SPRAY position.

ti14995a

4.Engage trigger lock. Put prime/relief valve UP to release pressure and rotate spray tip back to SPRAY position.

ti14994a

12

3A0153E