Alternate Priming Method
Inlet Valve Cleaning
Removal
1.Engage trigger lock and pull relief valve UP to release pressure.
ti14994a | ti14999a |
2. Remove material cup and suction tube.
3.Hold sprayer
ti15505a
NOTE: Make sure the spring also comes out. Use
ti15530a
4.Clean as much excess material from pump cavity as possible. Make sure you also clean spring (a),
Installation
NOTE: Before installing, make sure
1.Place inlet valve (b) with spring (a) on top of inlet fit- ting (d). Push inlet fitting up into pump cavity.
a
b c
d
ti15502a
2.Hold inlet in place and turn sprayer
ti15500a
3.Replace inlet fitting and use wrench and socket to tighten to 10
NOTICE
Do NOT
4.Use the
3A0153E | 19 |