Graco 258880, 258864 Materials, Starting a New Job or Refilling the Cup

Models: 258880 258864

1 24
Download 24 pages 35.11 Kb
Page 10
Image 10

Materials

Use only water-based or oil-based (mineral spirit-type) materials with flash point greater than 100° F (38° C). Do not use materials which state “FLAMMABLE” on the packaging. For more informa- tion about your material, request MSDS from distribu- tor or retailer.

Spraying certain materials may cause static build-up in the sprayer that can result in static shock to the user. If this occurs, first ensure the mate- rial has a flash point greater than 100° F (38° C) and does not state that it is FLAMMABLE anywhere on the package. If still feeling a static shock, the material likely contains a non-mineral spirits fluid such as, but not lim- ited to, xylene, toluene, or naphtha, which can build up static. Switch to an alternative material.

Use oil-based material outdoors or in a well-ventilated indoor area with a flow of fresh air.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

When spraying water-basedmaterials, flush the sprayer thoroughly with water.

When spraying non-water-basedmaterials, flush the sprayer thoroughly with mineral spirits or com- patible, oil-based flushing fluid.

Starting a New Job (or Refilling the Cup)

1.Engage trigger lock and put prime/relief valve UP to release pressure.

ti14994a

ti14999a

Setup

2.Use the Fine-Finish Optimizer cleaning tool to lightly push on inlet valve to make sure it moves up and down freely.

3.Install material cup liner, fill with material, and thread onto sprayer.

ti15474a

4.To prime pump, disengage trigger lock and trigger sprayer for 10 seconds. Then release trigger and put prime/relief valve DOWN to spray position.

ti14995a

ti15418a

ti15425a

 

5.Reverse spray tip to UNCLOG position and spray into waste area for five seconds. Then rotate tip back to SPRAY position. NOTE: Failure to perform this operation could result in poor spray pattern.

ti14991a

ti15491a

ti14985a

You are now ready to spray! If sprayer fails to prime, follow Alternate Priming Method (page 21) and/or Inlet Valve Cleaning (page 22).

10

3A0705E

Page 10
Image 10
Graco 258880, 258864 important safety instructions Materials, Starting a New Job or Refilling the Cup