Alternate Priming Method

Alternate Priming Method

1.Engage trigger lock and put prime/relief valve UP to release pressure.

ti14994a

ti14999a

2. Remove material cup and fill with flushing material.

4.Hold sprayer above sink or waste area, disengage the trigger lock, and quickly trigger sprayer until material comes out of the drain tube.

ti14995a

ti14991a

NOTE: Material can shoot out of the drain tube when performing this procedure. Be sure to wear appropriate safety equipment and point drain tube away from yourself when pulling the trigger,

5. Thread the material cup back onto sprayer.

3.With sprayer in prime mode, turn sprayer upside-down, remove strainer, and slowly pour flushing material into the intake tube until full.

6.Trigger the gun for 10 seconds then release the trig- ger and put the prime/relief valve DOWN to spray position.

ti15425a

7.Reverse spray tip to UNCLOG position and spray into waste area for five seconds to ensure sprayer has primed.

ti14995a

ti14991a

8.Sprayer is now ready to spray. Follow Starting New Job instructions on page 10.

3A0705E

21

Page 21
Image 21
Graco 258864, 258880 important safety instructions Alternate Priming Method