Models

Spring Operated Fluid Regulators

Part No.

Series

Maximum Fluid Inlet

Regulated Pressure

Gauge

Gauge Pressure

 

 

Pressure, psi (kPa, bar)

Range, psi (kPa, bar)

 

Range,

 

 

 

 

 

psi (kPa, bar)

214895

H

250 (1800, 18)

5–100 (34–700, 0.3–7)

No

n/a

214706L

H

250 (1800, 18)

5–100 (34–700, 0.3–7)

Yes (see

0–100 (0–700, 0–7)

 

 

 

 

below)

 

24A082 {

A

250 (1800, 18)

5–100 (34–700, 0.3–7)

Yes (see

0–100 (0–700, 0–7)

 

 

 

 

below)

 

255374 {

B

250 (1800, 18)

5–100 (34–700, 0.3–7)

Yes (see

0–200 (0–1400, 0–14)

 

 

 

 

below)

 

217314L

F

250 (1800, 18)

20–160 (140–1100, 1.4–11)

Yes

0–300 (0–2100, 0–21)

221118L

E

250 (1800, 18)

20–160 (140–1100, 1.4–11)

No

n/a

{ISO pitch thread inlet and outlet. Not compatible with US standard pitch. Fluid housing coated with PTFE polymer.

LThese models are and certified.

The fluid supply system’s main line pressures often exceed the pressure range of the gauge supplied with regulators 214706, 255374, and 24A082. Exposing this gauge to excessive pressure can damage the gauge, causing inaccurate readings and the needle will not return to zero.

This damage is not covered by the Graco warranty.

Air Operated Fluid Regulators

Part No.

Series

Maximum

Maximum Fluid

Regulated Pressure

Gauge

Gauge Pressure

 

 

Regulated

Inlet Pressure,

Range,

 

Range,

 

 

Air Pressure,

psi (kPa, bar)

psi (kPa, bar)

 

psi (kPa, bar)

 

 

psi (kPa, bar)

 

 

 

 

 

 

 

 

 

 

 

214980 }

F

30 (210, 2.1)

250 (1800, 18)

0–30 (0–210, 0–2.1)

Yes

0–30 (0–210, 0–2.1)

 

 

 

 

 

 

 

244375

B

100 (700, 7)

250 (1800, 18)

5–100 (34–700, 0.3–7)

No

n/a

 

 

 

 

 

 

 

}Regulated air pressures from 30–100 psi (210–690 kPa, 2.1–6.9 bar) may be used if a 100 psi rated gauge is installed.