Troubleshooting

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

Before servicing this equipment always make sure to Relieve the Pressure.

Check all possible remedies in the Troubleshooting Chart before disassembling the fluid regulator.

Problem

Cause

Solution

 

 

 

No pressure regulation

Damaged or clogged air regulator or

Clear obstruction in line, service regu-

 

line (214980 only)

lator if necessary.

 

 

 

 

Damaged diaphragm (22)

Replace diaphragm.

 

 

 

Fluid leaks from under cap

Loose cap (7)

Tighten screws (1) in sequence

 

 

shown in Service section.

 

 

 

 

Worn gasket (26)

Replace gasket.

 

 

 

Pressure creeps above setting

Damaged or clogged air regulator or

Clear obstruction in line, service regu-

 

line (214980 only)

lator if necessary.

 

 

 

 

Damaged diaphragm (22)

Replace diaphragm.

 

 

 

 

Seat leaking (16)

Replace ball (20), seat, and gasket

 

 

(15).

 

 

 

Pressure drops below setting

Damaged or clogged air regulator or

Clear obstruction in line, service regu-

 

line (214980 only)

lator if necessary.

 

 

 

 

Empty/clogged supply line

Fill/flush supply line.

 

 

 

 

Clogged air spray gun or fluid dis-

Replace, see gun or valve manual for

 

pensing valve.

service instructions.

 

 

 

 

Using regulator beyond its rated flow

Install additional regulators.

 

capacity, see the Technical Data on

 

 

Page 22.

 

 

 

 