Installation

Changing the Orientation of the Fluid Inlet and Outlet Ports

The pump is shipped with the fluid inlet (R) and outlet

(S)ports facing the same direction. See Fig. 4. To change the orientation of the inlet and/or outlet port:

1.Remove the screws and washers (106, 112, 113 and 114) holding the inlet (102) and/or outlet (103) manifold to the covers (101).

2.Reverse the manifold and reattach. Install the screws and washers and torque to 150–160 in–lb (17–18 NSm). See Torque Sequence, page 31.

Fluid Pressure Relief Valve

CAUTION

Some systems may require installation of a pres- sure relief valve at the pump outlet to prevent overpressurization and rupture of the pump or hose. See Fig. 5.

Thermal expansion of fluid in the outlet line can cause overpressurization. This can occur when using long fluid lines exposed to sunlight or ambi- ent heat, or when pumping from a cool to a warm area (for example, from an underground tank).

KEY

N1/2 npt(f) air inlet port P Muffler

Air exhaust port is 3/4 npt(f) .

R 2” fluid inlet flange S 2” fluid outlet flange

1Torque to 150–160 in–lb (17–18 NSm). See Torque

Sequence, page 31.

N

P

102

Fig. 4

101Fluid covers

102Fluid inlet manifold

103Fluid outlet manifold

106Fluid outlet manifold screws (top)

112Fluid inlet manifold screws (bottom)

113Fluid outlet manifold washer

114Fluid inlet manifold washer

103 106 1

113 S

101

R

114

112 1

04613B

Overpressurization can also occur if the Husky pump is being used to feed fluid to a piston pump, and the intake valve of the piston pump does not close, causing fluid to back up in the outlet line.

KEY

R2” fluid inlet flange

S2” fluid outlet flange

VPressure relief valve

Part No. 112119 (stainless steel)

1Install valve between fluid inlet and outlet ports.

2Connect fluid inlet line here.

3Connect fluid outlet line here.

S 3

V 1

2

R

 

04616B

Fig. 5

 

 

 

 

 

10 308550

Page 10
Image 10
Graco 308550ZAD Changing the Orientation of the Fluid Inlet and Outlet Ports, Fluid Pressure Relief Valve