Graco 308550ZAD Performance Chart, Feet meters, Psi MPa, bar, Fluid Flow GPM lpm

Models: 308550ZAD

1 36
Download 36 pages 47.92 Kb
Page 35
Image 35

Performance Chart

Example of Finding Pump Air Consumption and Air Pressure at a Specific Fluid Delivery and Discharge Head:

To supply 60 gpm (227 liters) fluid flow (horizontal scale) at 40 psi (0.28 MPa, 2.8 bar) discharge head pressure (vertical scale) re- quires approximately 60 scfm (1.68 m#/min) air consumption at 70 psi (0.48 MPa, 4.8 bar) inlet air pressure.

feet (meters)

280

(85.3)

240

(73.2)

200

(61.0)

160

(48.8)

120

(36.6)

80

(24.4)

40

(12.2)

0

psi

(MPa, bar)

120

 

 

 

 

 

 

 

 

 

(0.8, 8)

A

 

 

INLET AIR PRESSURES

 

 

 

 

 

A 120 psi air (0.8 MPa, 8 bar)

 

 

 

 

E

 

100

 

 

 

B 100 psi air (0.7 MPa, 7 bar)

 

B

 

 

(0.7, 7)

 

C 70 psi air (0.48 MPa, 4.8 bar)

F

 

 

D40 psi air (0.28 MPa, 2.8 bar)

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0.56, 5.6)

 

 

 

 

 

 

 

 

AIR CONSUMPTION

 

 

 

 

 

G

 

 

 

E

25 scfm (0.70 m#/min)

 

 

 

C

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

F

50 scfm (1.40 m#/min)

 

 

 

 

 

 

 

 

 

 

 

 

(0.42, 4.2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

G

75 scfm (2.10 m#/min)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

100 scfm (2.80 m#/min)

 

40

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

(0.28, 2.8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 (0.14, 1.4)

0

0

30

60

90

120

150

 

(114)

(227)

(341)

(454)

(568)

FLUID FLOW GPM (lpm)

TEST CONDITIONS

KEY

 

FLUID PRESSURE AND FLOW

 

Pump tested in water with PTFE diaphragm and inlet

 

 

SCFM AIR CONSUMPTION

submerged.

 

 

 

 

 

308550 35