Adjusting the Spray Pattern

1.To achieve full fan pattern, open the pattern adjust- ment valve (25) by turning the knob fully counter- clockwise.

(Close)

(Open)

25

ti4841a

FIG. 7

2. Trigger gun and adjust gun air pressure:

 

 

Hose Inlet Air

 

Gun Inlet Air

Pressure

 

PSI (kPa, bar)

 

Pressure

25 ft 5/16 in.

 

PSI (kpa, bar)

(7.9 mm) ID hose

 

 

 

HVLP Gravity

29 (210, 2.1)

50 (345, 3.4)

 

 

 

HVLP

40 (280, 2.8)

72 (480, 4.8)

Pressure

 

 

 

 

 

Compliant

29 (210, 2.1)

41 (280, 2.8)

 

 

 

Airspray

40 (280, 2.8)

52 (345, 3.4)

gravity feed

 

 

 

 

 

Airspray

40 (280, 2.8)

56 (410 4.1)

pressure feed

 

 

 

 

 

WARINING

PRESSURIZED EQUIPMENT HAZARD

To avoid injury, never open the fluid adjustment knob (21) beyond the one half turn indicated in step 3 in Adjusting the Spray Pattern. If the red band on the knob stem (21) is visible, the knob is not adjusted correctly and could result in serious injury. Repeat step 3 in Adjusting the Spray Pattern.

Setup

3.To establish the correct fluid flow, turn the fluid adjustment knob (21) counterclockwise until no restriction of the trigger movement is felt, then turn out another half turn. When the knob is turned far enough, the trigger should be able to touch the gun handle when the gun is triggered.

(Open)

(Close)

21

ti4840a

FIG. 8

4.Pressure feed only: Adjust fluid pressure to achieve desired fluid flow rate

5.To reduce fluid flow, turn the fluid adjustment knob (21) clockwise.

• If the fluid adjustment knob is turned clockwise all the way, the gun will emit only air.

If you cannot achieve the correct fluid flow with the fluid adjustment knob, a different sized noz- zle may be necessary. For smaller fluid flow, use the next size smaller nozzle. For a larger fluid flow, use the next size larger nozzle.

(Open)

(Close)

21

ti4840a

FIG. 9

6.Spray a test pattern. Evaluate the spray pattern size and atomization.

310692C

11

Page 11
Image 11
Graco 310692C manual Adjusting the Spray Pattern, Warining