Service

Replacing the air and fluid packings

Tools needed:

Gun Tool - provided

Packing Installation Tool - provided

Adjustable Wrench

Screw Driver

Lubricant part no. 111265; see Accessories, page 28, to order

Compatible Solvent

• Order Repair Kit 234828. See Parts starting on page 25.

Clean parts with a solvent that is compatible with the parts and the fluid being sprayed.

Lightly lubricate the parts indicated with lubri- cant 111265.

Disassembling the gun

WARNING

Follow Pressure Relief Procedure, page 13 when you stop spraying and before cleaning, checking, ser- vicing, or transporting equipment. Read warnings, page 3.

1. Relieve the pressure, page 13.

Service

2.Flush the spray gun, page 9.

3.Remove the air cap retaining ring (15A), seal (15B), and air cap (14).

15A 15B 28 12

14

ti4849b

FIG. 24

4.Trigger the gun while you remove the fluid nozzle (12) with the gun tool (28). See FIG. 24.

5.Remove the screw (11), pin (17), wave washer (18), and trigger (10).

17

18

11

10

ti4828a

FIG. 25

310692C

19

Page 19
Image 19
Graco 310692C manual Service, Replacing the air and fluid packings, Disassembling the gun