Installation

InstallationSetup

1.Insert rubber feet of control box through holes in plate (4). Mount control box (2) on the XM frame using plate (4), bolts (7), and nuts (6).

2

7

7

4

6

ti20973a

FIG. 1: Mount Control Box

2.Place bracket (5) on top of the control box (2) and mount to the XM frame using screws (7) and nuts

(6).

6

2

5

7

ti20974a

FIG. 2: Mount Plate

Installing this equipment requires access to parts that may cause electric shock or other serious injury if work is not performed properly. Have a qualified elec- trician connect power and ground to power switch ter- minals; see manual 3A2980 and FIG. 4 on page 6. Be sure your installation complies with all national, state, and local safety and fire codes.

Connect Power Cable Wires

1.Turn off power to junction box (J).

2.Replace the supplied liquid-tight conduit connector

(C) with cord restraint fitting (8). Thread the three wires of the power cord to the opposite side of the cabinet for connection to the power inlet at the main disconnect (D). See FIG. 3.

3.Secure the service wires to 1L1 and 3L2 using a #2 Phillips or Pozidriv M3,5 Form 2 screwdriver. Tighten to 7 in-lb (0.8 N•m).

4.Connect the external ground bond wire (Green or Green/Yellow) to the protective earth lug (PE). Secure with a 3/8 or 7/16 flat-bladed screwdriver. Tighten to 35 in-lb (4 N•m).

C

1L1

D

3L2

3L2

PE

 

ti19942a

FIG. 3: Main Disconnect Electrical Connections

NOTICE

Route power cable (3) to avoid interference with moving parts. See FIG. 4.

313258C

5

Page 5
Image 5
Graco 313258C important safety instructions InstallationSetup, Mount Control Box