Startup

Startup

1. Turn pressure control to lowest pressure.

ti22222a

2. Turn power ON.

ti5303a

ON

OFF

3.Increase pressure 1/4 turn to start motor. Allow fluid to circulate through drain tube for 15 seconds.

1/4 turn

ti22223ati10167a

4. Turn prime valve horizontal. Disengage trigger lock.

ti22221a

5.Hold gun against grounded metal flushing pail. Trigger gun and flush 1 minute.

ti5310b

High-pressure spray is able to inject toxins into the body and cause serious bodily injury. Do not stop leaks with hand or rag.

6.Inspect for leaks. If leaks occur, perform Pressure Relief, page 10. Tighten fittings.

7.Place siphon tube in paint pail.

TIA

8.Trigger gun again into flushing pail until paint appears.

ti5310c

9.Move gun to paint pail and trigger for 20 seconds. Engage trigger lock.

ti5310e

10.Screw tip assembly onto gun. Tighten. For gun assembly instructions, see separate gun manual.

ti2710a

14

332758A

Page 14
Image 14