9. Raise siphon tube above flushing fluid.

Cleanup

13.Remove filter from gun if installed. Clean and inspect. Install filter. See separate gun manual.

ti5848a

Flushing

Fluid

10.Close prime valve. Trigger gun into flushing pail to purge fluid from hose.

Flush

ti22221a

11.Turn pressure control knob all the way down and power switch OFF. Unplug sprayer.

ON

OFF

ti22222a

12.If you have a filter installed on your sprayer, remove filter. Clean and inspect. Install filter.

ti22225a

ti22224a

14.If flushing with water, flush again with mineral spirits or Pump Armor to leave a protective coating to pre- vent freezing or corrosion.

Pump Armor

ti2895a

15.Wipe sprayer, hose and gun with a rag soaked in water or mineral spirits.

ti2776a