Graco 3A0149E RAC SwitchTips, for use with G40 RAC Air Cap, LTX RAC Spray Tips

Models: 3A0149E

1 40
Download 40 pages 24.37 Kb
Page 33
Image 33

Spray Tip Selection Chart

AAF Fine Finish Pre-Orifice Spray Tips

Recommended for high finish quality applications at low and medium pressures. AAF tips have a pre-orifice that assists in atomizing sheer thinning materials, including lacquers.

Order desired tip, Part No. AAFxxx, where xxx = 3-digit number from matrix below.

 

* Fluid Output

 

Maximum Pattern Width at 12 in. (305 mm)

 

 

fl oz/min (lpm)

 

 

 

in. (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 to 6

6 to 8

8 to 10

 

10 to 12

12 to 14

14 to 16

Orifice Size

at 600 psi

at 1000 psi

(150)

(200)

(250)

 

(300)

(350)

(400)

 

 

 

 

 

 

 

in. (mm)

(4.1 MPa, 41 bar)

(7.0 MPa, 70 bar)

 

 

Spray Tip

 

 

 

 

 

 

 

 

 

 

 

 

0.009 (0.229)

7.0 (0.21)

8.5 (0.25)

208

308

408

 

 

 

 

0.011 (0.279)

9.5 (0.28)

12.5 (0.37)

210

310

410

 

510

610

710

 

 

 

 

 

 

 

 

 

 

0.013 (0.330)

12.0 (0.35)

16.0 (0.47)

212

312

412

 

512

612

712

0.015 (0.381)

16.0 (0.47)

21.0 (0.62)

 

 

414

 

514

614

714

0.017 (0.432)

20.0 (0.59)

26.5 (0.78)

 

 

416

 

516

616

716

 

 

 

 

 

 

 

 

 

 

*Tips are tested in water.

Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT) P where QT = fluid output (fl oz/min) at 600 psi from the above table for the selected orifice size.

RAC SwitchTips, for use with G40 RAC Air Cap

NOTE: All tips in the Spray Tip Selection Charts below can be used with Model G40 guns equipped with RAC air cap 24C921.

NOTE: Tips are sometimes packaged with other promo- tional parts intended for the airless market. Disregard extra parts.

LTX RAC Spray Tips

Order desired tip, Part No. LTXxxx, where xxx = 3-digit number from matrix below.

 

 

 

 

Maximum Pattern Width at 12 in. (305 mm)

 

 

* Fluid Output,

 

 

 

 

in. (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 to 4

4 to 6

6 to 8

8 to 10

10 to 12

12 to 14

14 to 16

16 to 18

18 to 20

 

at 2000 psi

 

(100)

(150)

(200)

(250)

(300)

(350)

(400)

(450)

(500)

Orifice Size in.

(14.0 MPa, 140 bar)

(mm)

fl oz/min (lpm)

 

 

 

 

Spray Tip

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.009 (0.229)

11.2 (0.33)

109

209

309

409

509

 

 

 

 

0.011 (0.279)

16.6 (0.49)

111

211

311

411

511

611

 

 

 

0.013 (0.330)

23.3 (0.69)

 

213

313

413

513

613

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.015 (0.381)

30.8 (0.91)

115

215

315

415

515

615

 

 

 

0.017 (0.432)

39.5 (1.17)

 

217

317

417

517

617

 

817

 

0.019 (0.483)

49.7 (1.47)

 

219

319

419

519

619

 

819

 

 

 

 

 

 

 

 

 

 

 

 

0.021 (0.533)

60.5 (1.79)

 

221

321

421

521

621

721

821

 

0.023 (0.584)

72.7 (2.15)

 

 

323

423

523

623

723

 

 

0.025 (0.635)

85.9 (2.54)

 

225

325

425

525

625

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.027 (0.686)

100.0 (2.96)

 

227

327

427

527

627

 

827

 

0.029 (0.737)

115.6 (3.42)

 

 

329

429

529

629

729

 

 

0.031 (0.787)

131.8 (3.90)

 

231

331

431

531

631

 

831

 

 

 

 

 

 

 

 

 

 

 

 

0.033 (0.838)

149.4 (4.42)

 

 

 

433

533

633

 

833

 

0.035 (0.889)

168.4 (4.98)

 

235

335

435

535

635

735

835

 

*Tips are tested in water.

Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT) P where QT = fluid output (fl oz/min) from the above table for the selected orifice size.

Measured with NO airflow. Air assist will tend to reduce pattern lengths by 1 in. to 2 in.

3A0149E

33

Page 33
Image 33
Graco 3A0149E RAC SwitchTips, for use with G40 RAC Air Cap, AAF Fine Finish Pre-Orifice Spray Tips, LTX RAC Spray Tips